18
ENGLISH
4.5) Return to original factory settings / fi rmware version
Select screen 10 from the “main menu” (Ref. to § 4.1), to return the pump to its factory setting hold
the finger on the button (4) until a confirmation “beep” is heard.
The RESET screen also shows the fi rmware version of the control board.
4.6) Errors/Malfunctions
These appear on the display during operation, combined with a beep to notify the operator of
procedural or operational errors. They are accompanied by an audible signal and the Cembre
logo (8) lighting up yellow.
Message Error description
Solution
ERROR
Ï
Ð
In CRIMPING mode, a 100 bar pres-
sure has been reached or exceeded
but the oil discharge has been acti-
vated before waiting for the motor
to be automatically switched off .
Repeat the work cycle, keeping the start but-
ton pressed down until the motor switches off
automatically.
The pump has been started with-
out the fl exible hose connected or
the fl e-xible hose is not correctly
connected.
Press the release button, connect the fl exible
hose or check the correct connection to the
pump.
NTC
FAULT
Interruption of the signal from the
NTC temperature probe of the
battery.
Replace the battery. If the problem persists,
please contact Cembre.
001
Ï
Ð
Abnormal power consumption of
the motor.
The pump stops.
Wait for the display to turn off (60 sec.) or remove
and re-insert the battery, then re-start the
pump, if the problem persists, please contact
Cembre.
002
Ï
Ð
Output voltage of the pressure trans-
mitter is out of the pre-set range.
The pump stops and doesn't re-start.
Remove and re-insert the battery, if the prob-
lem persists, please contact Cembre.
003
Ï
Ð
Failure to reach the set pressure
within 120 sec. of continuous opera-
tion of the pump.
Repeat the work cycle; if the problem persists,
please contact Cembre.
004
Ï
Ð
Overcharging of the battery with
protection tripping.
The pump stops.
Wait for the display to turn off (60 sec.) or re-
move and re-insert the battery, then re-start the
pump. if the problem persists, please contact
Cembre.
Errors 00.. are displayed for about 30 seconds before being reset, but will display repeat-
edly in the event of permanent anomalies.
RESET
SW: S1J56100