6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
MSR lamp
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1.5 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the XR10 SPOT requires the assistance of specialised personnel for
all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering are damaged. Their respective
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
6.5 Level of protection against the penetration of solid and liquid objects:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid objects is IP 20.
For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
• Raincover for XR base (top) (cod. 03.MA001)
• Raincover for XR base (bottom) (cod. 03.MA002)
XR10 SPOT uses a PHILIPS 575/2 (other reccomended lamps: Philips 575 MSD).
ARC 1200
2M
8
F
!
!
UV
XR10 SPOT