DTS XR700 SPOT Manuale utente

Categoria
Proiettori
Tipo
Manuale utente
GB
Made in Italy
XR700 SPOT
Users Manual Rel 1.2
D.T.S. Illuminazione srl - ITALY
http://www.dts-lighting.it
Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia
non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo
documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso
scritto della D.T.S .
DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di
design a ciascun proprio prodotto. D.T.S non assume alcuna responsabilità sull’uso o sull’applicazione dei
prodotti o dei circuiti descritti.
The information contained in this publication has been carefully prepared and checked. However, no
responsibility will be taken for any errors. All rights are reserved and this document cannot be copied,
photocopied or reproduced, in part or completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products
without prior notice. D.T.S. assumes no responsibility for the use or application of the products or circuits
described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand
soin. Nous déclinons toutefois toute responsabilité en cas d'éventuelles inexactitudes. Tous droits
réservés. Ce document ne peut être copié, photocopié ou reproduit, dans sa totalité ou partiellement,
sans le consentement préalable de .
se réserve le droit d'apporter toutes modifications et améliorations esthétiques, fonctionnelles ou
de design, sans préavis, à chacun de ses produits. décline toute responsabilité sur l'utilisation ou
sur l'application des produits ou des circuits décrits.
D.T.S
D.T.S.
D.T.S.
Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y
controladas. Con todo, no se asume ninguna responsabilidad por eventuales inexactitudes.
Todos los derechos han sido reservados y este documento no puede ser copiado, fotocopiado
o reproducido, total o parcialmente, sin previa autorizaciónescrita de
se reserva el derecho a aportar sin previo aviso cambios y modificaciones de carácter
estético, funcional o de diseño a cada producto suyo. no se asume responsabilidad de
ningún tipo sobre la utilización o sobre la aplicació
n de los productos o de los circuitos descritos.
D.T.S.
D.T.S.
D.T.S.
ARC 1200
XR700 SPOT
2
3
ARC 1200
XR700 SPOT
INDEX:
1- SYMBOLS 4
2- GENERAL WARNING 4
3- GENERAL WARRANTY CONDITION 4
4- TECHNICAL FEATURES 5
5- ACCESSORIES 7
6- IMPORTANT SAFETY INFORMATION 8
6.1 Fire prevention
6.2 Prevention of electric shock
6.3 Protection against ultraviolet radiation
6.4 Safety
6.5 Level of protection against the penetration of solid and liquid objects
7- MOUNTING THE LAMP 9
7.1 Lamp alignment
8- VOLTAGE AND FREQUENCY 10
9- INSTALLATION 10
9.1 Safety cable
9.2 Protection against liquids
9.3 Movement
9.4 Risk of fire
9.5 Forced ventilation
9.6 Ambient temperature
10- MAINS CONNECTION 11
10.1 Protection
11- DMX SIGNAL CONNECTION 12
11.1 DMX Addresses
11.2 Selecting the DMX address
12- FIRMWARE UPDATING 13
13- DISPLAY FUNCTIONS 14
14- PAN & TILT SPEED 17
15- FANS SPEED
16- ERROR MESSAGES 17
17- HIDDEN MENU 18
18- OPENING THE PROJECTOR HOUSING 19
19- REPLACING GOBOS
20- PERIODIC CLEANING 20
20.1 Lenses and reflectors
20.2 Fans and air passages
21- PERIODIC CONTROLS
22- DMX PROTOCOL 21
23- 8 MOTORS CONTROL CARD 36
24- 6 MOTORS CONTROL CARD 37
25- PAN & TILT CARD 38
26- CABLES RESEND CARD
27- DISPLAY CARD
28- LAMP ON-OFF CONTROL CARD
29- ROTATING GOBO WHEEL 39
30- FIXED GOBO WHEEL 40
31- COLOUR WHEEL 1 41
32- COLOUR WHEEL 2 42
ARC 1200
1- SYMBOLS
Graphic symbols used on this manual
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important information
regarding safety during installation , use and maintenance.
The device is not for domestic use and must be installed by a qualified electrician or experienced
person.
Always disconnect the device from the mains before replacing the lamp.
The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating.
The device must always be equipped with an efficient ground connection.
3- GENERAL WARRANTY CONDITIONS
The unit is guaranteed for 24 months from the date of purchase against manufacturing material defects.
THIS SYMBOL INDICATES A HOT SURFACE
THIS SYMBOL INDICATES ELECTRIC SHOCK RISK
THIS SYMBOL INDICATES GENERAL RISK
THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON
INFLAMMABLE SURFACES”
2M
THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO
BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT
4
F
THIS SYMBOL MEANS “RADIATION FROM THIS LAMP
CAN CAUSE DAMAGE TO EYES AND SKIN”
!
UV
XR700 SPOT
ARC 1200
4- TECHNICAL FEATURES
The XR700 SPOT is a brand new moving head fitted with a 700W discharge lamp, which delivers a
massive 27.000 Lux at 5 m (10°).
The XR700 SPOT is fitted with a Philips MSR Gold 700/2 Fastfit lamp (50.000 Lumens) combined with a
dichroic parabolic reflector.
The XR700 SPOT is one of the most complete moving heads in the 700W range and is particularly
suitable for all professional applications, both mobile (concerts, shows, tours, special events) and fixed
(clubs and other venues), requiring a light with extremely high luminous output and versatility of
functions.
The XR700 SPOT in fact features a very flexible colour generation, thanks to two colour wheels with 7
colours each, with linear selection for perfect 2-colour beams, and also 2 colour conversion filters
(3200°K and 5600°K).
The XR700 SPOT incorporates also motorized focussing, motorized iris, motorized linear zoom (10°-
30°), 3-facet rotating prism, 1 wash effect filter.
2 gobo wheels are available, featuring respectively: 7 rotating and 16 bit indexable gobos
(interchangeable); 8 fixed gobos (interchangeable).
The XR700 SPOT also includes a new Pan / Tilt locking system with recessed buttons and electronic
ballast.
The XR700 SPOT is the ideal moving head as well for all applications in which noiseless operation is
required, thanks to its silent internal ventilation system and silent pan/tilt operation.
XR 700 SPOT (Cod. 03.MS006.EB.L)
• Electronic ballast 90-260V 50/60 Hz • Black colour
Also available in white (RAL 9003) colour on demand.
Lamp
Lamp: Philips MSR Gold 700/2 Fastfit
Automatic switching ON of lamp in case of accidental switching OFF.
Lamp ON/OFF via DMX; Reset via DMX.
Optical group
27.000 Lux at 5 m (10°)
Dichroic glass reflector
Focus
Motorized focus
Iris
Motorized iris (16 bit)
Zoom
Motorized zoom (10°- 30°)
5
XR700 SPOT
4- TECHNICAL FEATURES
Dimmer / shutter / strobo
Linear dimmer
Shutter
Strobe from 0,85 flash/sec to 6,75 flash/sec
Power saving mode (the lamp dims to 50% six seconds after shutter closure)
Colours
2 Colour wheels (7 colours + open with linear selection)
3200°K and 5600°K colour conversion filters
Colour change with blackout sync; rainbow effect
Gobos
2 gobo wheels: 1 rotating (7 indexable 16 bit gobos + open) and 1 fixed (8 gobos + open)
Extractable gobo holders for both wheels
Gobo change with synchronized blackout
Gobo scrolling; Gobo shake
Effects
Indexable prism rotating in both directions (3-facet)
Wash effect filter
Pan / Tilt
Pan 540° (3,9 sec.)
Tilt 270° (2,6 sec.)
16-bit resolution
2-Speed function (2 selectable pan/tilt speeds); extremely smooth and precise movements even at the
highest speeds
Pan / Tilt locking system with recessed buttons
Automatic Pan/Tilt repositioning in case of knocks
25 DMX channels (Default)
Internal operating system updatable via DMX
Connections
4 XLR connectors (3-pole In and Out; 5-pole In and Out) by Neutrik
POWERCONN connector by Neutrik
Power supply
Electronic ballast: 90 - 260 V (50/60 Hz)
Power consumption: 820 W
Standard accessories
2 x “C” GQuick clamps with “fastlock” connection
Thermal
Operating ambient temperature: -10° / 40°
Weight
31,5 Kg (electronic ballast)
ARC 1200
6
XR700 SPOT
4- TECHNICAL FEATURES
Dimensions
5- ACCESSORIES
As standard
•1 x MSR Gold 700/2 Fastfit lamp
•1 x POWERCONN male cable connector (cod. 0520P014)
•1 x XLR 5 Pins male cable connector (cod. 0508B028)
•1 x XLR 5 Pins female cable connector (cod. 0508B027)
•2 x “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• User’s manual
Optional (on request)
• Wireless DMX receiver card (cod. 03.LA.012)
• “C” Clamp G60 black (max. load 50Kg) (cod. 0521A004)
• “C” Clamp G60 chrome (max. load. 50Kg) (cod. 0521A004.20)
• “C” Clamp GQUICK with “Fast Lock” connection 1/4 turn (max. load. 80Kg) (cod. 0521A014)
• “C” Clamp G100 black / professional (max. load. 200Kg) (cod. 0521A015)
• Omega clamp with “Fast Lock” connection 1⁄4 turn (cod. 02K00467)
• Safety wire (3mm x 60 cm), ring spring catch, max. capacity load 60Kg (cod. 0521A010)
Unit Dimensions (LxWxH)
525x500x810mm
Weight: 31,5 Kg
Packaging Dimensions (LxWxH)
610 x 540 x 720 mm
Weight: 37 Kg
ARC 1200
7
XR700 SPOT
408 mm
625 mm
500 mm
415 mm
18 0 mm
525 mm
270°
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
MSR Gold 700 Fastfit lamp
The use of any other alternative lamp is not recommended and will null and void the fixture's warranty.
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1.5 MT.
-Minimum distance from the closest illuminable surface: 2 MT.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Unplug the unit prior to performing any function which involves
touching the inside of the moving head, including lamp replacement.
-The level of technology inherent in the XR700 SPOT requires the assistance of specialised personnel for
all servicing. Please refer to an authorised DTS service centre.
-A good earth connection is essential for proper functioning of the projector.
-Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Protection against ultraviolet radiation:
-Never turn on the lamp if any of the lenses, filters or ABS covering are damaged. Their respective
shielding functions will only operate efficiently if they are in perfect working order.
-Never look directly the lamp when it is on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety cable to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 70°C. Never handle the unit until at
least 10 minutes have elapsed since the lamp was turned off.
-Always replace the lamp if any physical damage is evident.
-Never install the fixture in an enclosed area lacking sufficient air flow. The ambient temperature should
not exceed 40°C.
-A hot lamp may explode, so always wait for at least 10 minutes prior to attempting to replace the lamp.
-Always wear suitable hand protection when handling the lamp.
6.5 Level of protection against the penetration of solid and liquid objects:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid objects is IP 20.
For outdoor use, D.T.S. reccomend the use of the dedicated raincovers:
• Raincover for XR base (top) (cod. 03.MA001)
• Raincover for XR base (bottom) (cod. 03.MA002)
XR700 SPOT uses a PHILIPS /2
ARC 1200
2M
8
F
!
!
UV
XR700 SPOT
7- MOUNTING THE LAMPS
Warning: Switch off the unit before replacing the lamp.
1) Using a screwdriver, loose the 3 screws A, B, C, (photo 1) and remove the metal cover .
2) Insert the lamp (photo2).
3)Rotate the lamp 1/4 turn clockwise (photo 3 and 4).
The lamp used on XR700 SPOT is made in quartz glass and should be handled with care. Always follow
the instructions supplied in the lamp's packaging. Never touch the glass directly but use the tissue
provided in the lamp's packaging. The lamp socket is not symmetrical.
DO NOT USE UNDUE FORCE ON THE GLASS. In case of difficulty, read again the instructions and repeat
the procedure.
4) Replace the metal cover and tighten the screws A,B,C, which were previously removed.
WARNING: Never look directly at the lamp when it’s lit.
Discharge lamps emits UV rays; radiation from this lamp can cause damage to eyes and skin.
7.1 Lamp alignment
Attention: we recommend to align the lamp in the optical system to avoid overheating of the dichroic
filters and other components inside the unit. The lamp alignment is also essential to obtain the
maximum unifirmity and luminous performance by the projection.
3 adjusters X, Y and
Z (photo 5)
you will have an evenly projected light beam, with no shadows or
zones wich are brighter than others.
Philips MSR Gold 700/2 Fastfit
Power 700W
Luminous flux 50,000 lm
Colour temperature 7.500°K
Lampbase PGJX50
Rated life 750 hours
PGJX50
1) Mount the fixture in an orientation so that it may be squarely projected onto a smooth white surface
no less than 3 meters away. 2) Using a console or the menu system, focus an open (white) beam onto
the surface and observe the beam. 3) Using a phillips-head screw driver, rotate the
until you achieve a uniform flat field.
When the lamp is correctly optimized,
ARC 1200
Photo 2Photo 1 Photo 4Photo 3
Photo 5
9
Lamp
Alignment
UV
XR700 SPOT
8- VOLTAGE AND FREQUENCY
The XR700 SPOT with electronic ballast can operate at 90-260 VOLT 50 or 60 Hz.
9- INSTALLATION
XR700 SPOT may be either floor or ceiling mounted.
For floor mounting installations, the XR700 SPOT is supplied with four rubber mounting feet on the
base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hang it. The structure should also be sufficiently rigid so as not to
move or shake whilst the XR700 SPOT is moving.
Four quarter turn fast locks placed on the base of the units, allows by using the two fast lock C clamps
provided in the box, to fix the unit in any position.
.
9.1- Safety cable
We recommend the use of a safety cable connected to the XR700 SPOT and to the suspension truss in
order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron
cable can bear the weight of the entire unit.
You may attach the safety cable to the two holes (A) located on the base of the fixture, as shown in the
picture below.
9.2- Protection against liquids
The projector contains electric and electronic components which should under no circumstances come
into contact with oil, water or any other liquid. The proper unit functioning would be compromised
should this occur.
A
ARC 1200
!
240 mm
105 mm
10
XR700 SPOT
9.3- Movement
The projector has a maximum movement of 540° for Pan and 270° for Tilt. DO NOT place any
obstructions in the path of the projector's movement.
9.4- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
9.5- Forced ventilation
You will note, on inspection, that the unit features various air inlets and cooling fans located on both the
base and head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
9.6- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
10- MAINS CONNECTION
XR700 SPOT with electronic ballast operate at 90-260 VOLT 50-60 Hz.
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 8 amps at 230V,
Or16 amps at 100-120 V
Strict adherence to regulatory norms is strongly recommended.
10.1- Protection
The use of a thermal magnetic circuit breaker is recommended for each XR700 SPOT.
A good earth connection is essential for the correct operation of the projector.
540°
270°
ARC 1200
11
2M
F
Electronic ballast
90-260V 50 / 60Hz
Fuse Holder
(12A T 5x20 Fuse)
!
WARNING
Do not place any object in the path
of the projector’s movement
!
XR700 SPOT
11- DMX SIGNAL CONNECTION
The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the
projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a XLR
5 or 3 pins connector. Ensure that the conductors do not touch each other. Do not connect the cable
ground to the XLR chassy
The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect it
to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the
second one.
In this way, all the projectors are cascade connected.
NB. If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX address not valid
- DMX reception problem
For Installations where long distance DMX cable connections are needed, we suggest to use a DMX
terminator.
The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor
Between pin 2 and 3.
The DMX terminator must be plugged into the last unit (DMX out panel connector) of the DMX line.
1
2
3
5
4
OUT
120 ohm
PIN 3
PIN 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE
LAST UNIT CONNECTED TO THE DMX LINE
ARC 1200
12
5
3
4
2
1
1=GND
2=DATA-
3=DATA+
CONTROLLER
S T A N D A R D
D M X 5 1 2
XR700 SPOT
11.1-DMX Addresses
XR700 SPOT can be controlled with 18, 25 (default) or 26 DMX channels.
If you want to use the unit in 25 channels mode (default), set the following addresses on the mixer:
Projector 1 A001
Projector 2 A026 If you want to select the next projector, just add “25”
11.2-Selecting the DMX address
1) Press the UP-DOWN key until you reach the required DMX channel. The numbers on the display will
start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop flashing and the
projector is now setted to the new DMX address.
TRICKS:
if you keep pushed the UP or DOWN keys, the channels are calculated more quickly and you get a
faster selection.
Projector 3 A051
….. A….
projector 6 A126
12 FIRMWARE UPDATING
Warning:
This procedure require a base knolewge of computer applications and Windows
Hyperterminal program.
To update the software version of the XR700 SPOT you need:
D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008).
USB-DMX Driver for the D.T.S. RED BOX interface .
(The driver and the installation procedure are available in our web site www.dts-lighting.it)
Updated software version.
Please follow the below procedure to perform the updating:
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using Windows Hyperterminal program.
It will be possible to download the software from the reserved area of D.T.S. web site:
www.dts-lighting.it.
Please refer to an authorised DTS service centre.
ARC 1200
13
!
XR700 SPOT
13- DISPLAY FUNCTIONS
DISPLAY FUNCTIONS
The XR700 SPOT display panel shows all the available functions . Using these functions, it is
possible to change some of the parameters and add some functions. Changing the DTS setting
can vary the functions of the unit so that it does not respond to the DMX 512 used to control it.
Carefully follow the instructions below before carrying out any variations or selections.
NOTE: the symbol shows which key has to be pushed to obtain the desired function.
Up-DownMENU ENTERUp-Down
PAN MOVEMENT INVERSION
To reverse Pan movement from left
to right and vice versa
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTERUp-Down
TILT MOVEMENT INVERSION
To reverse Tilt movement from
bottom upwards and vice versa
Up-Down
Counterclockwise
Clockwise
Up-DownMENU ENTER
DMX MODE
To select DMX mode : 25 (default),
26 or18 DMX channels
25 CHANNELS
(Pan & Tilt 16 bit)
18 CHANNELS
(Pan & Tilt 16 bit)
Up-Down
Up-Down
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
Up-Down
MENU
ENTERUp-Down
REVERSE DISPLAY
Reverses display's reading depending on
the mounting position
(On the ground or suspended).
Up-Down
Floor
position
Suspension
position
Up-DownENTER
Up-DownENTER
DISPLAY STAND BY
To turn off the display (after 5 seconds)
Or leave it always on.
Display OFF
Display
always ON
ENTER
ENTER
ENTER
ENTER
DMX IN
DMX OUT
DISPLAY
MENU
ENTER
DOWN
UP
MAINS
Electronic ballast
90-260V 50 / 60Hz
FUSE
12 A T 5x20
ARC 1200
14
XR700 SPOT
DMX IN
DMX OUT
Default
Same fixture as XR9 SPOT
26 CHANNELS
(Pan & Tilt 16 bit)
MENU
ENTER
DEFAULT
To restore default setting
ENTER
Up-Down
MENU ENTER
Fan control
To control the fan speed .
Up-Down
ENTER
Up-Down
(DEFAULT : 5 )
MENU ENTER
Up-Down
ENTER
ENTER
Up-Down
(DEFAULT : 2 )
SPEED control
Pan&Tilt Speed control.
13- DISPLAY FUNCTIONS
ENTER
MENU
Up-Down
ENTER
MENU
Up-Down
ENTER
Up-Down
GOBO ROTATION DURING GOBO SCROLLING
DISABLED (DEFAULT)
.
ENTER
SOFTWARE
Software version for 8 motors and Pan&Tilt circuit
Boards
MENU
Up-Down
RESET
Al motors reset
RESET ENABLED VIA DMX
RESET DISABLED VIA DMX
TOTAL RESET
ENTER
ENTER
ENTER
ENTER
Up-Down
.
ARC 1200
XR700 SPOT
FACTORY SETTINGS
8 MOTORS CIRCUIT BOARD (4.1) AND
PAN&TILT CIRCUIT BOARD (2.7)
15
LAMP
Lamp always ON-always OFF
Or lamp ON-OFF selectable via DMX
ENTER
FORCED ON
ENTER
FORCED OFF
ENTER
ON / OFF VIA DMX (default)
MENU
Up-Down
ENTER
Up-Down
ENTER
Up-Down
ADJUST
To adjust the lamp with no mixer connected.
It’s possible to set the parameters for
PAN, TILT, FOCUS and ZOOM
ENTER
STRIKE
Lamp strikes counter
ENTER
Up-Down
MENU
Up-Down
ENTER
AUTO FOCUS
Automatic focusing during Zoom adjustment
.
Up-Down
AUTOMATIC FOCUS DISABLE (DEFAULT)
AUTOMATIC FOCUS ENABLE
ENTER
ENTER
GOBO1 Rotation
Gobo1 Rotation during gobo scrolling
GOBO ROTATION DURING GOBO SCROLLING
ENABLED
ENTER
MENU
Up-Down
ENTER
RESERVED
Pan lock-Tilt lock, Pan free-Tilt free and
System Reboot
Up
ENTER
.
ENTER
Up-Down
ENTER
ENTER
Up-Down
ENTER
ENTER
Up-Down
ENTER
Up-Down
.
ENTER
ENTER
ENTER
Up-Down
ENTER
ENTER
ENTER
Up-Down
.
.
ENTER
PAN LOCK
LOCK THE PAN TO THE DESIRED VALUE
TILT LOCK
LOCK THE TILT TO THE DESIRED VALUE
PAN FREE
REMOVE POWER TO PAN MOTOR
TILT FREE
REMOVE POWER TO TILT MOTOR
MENU ENTER
TIMER
lamp life TIME (reset possible)
and total UNIT LIFE TIME (reset not possible)
Up-Down
ENTER
Up-Down
ENTER
Up-Down
ENTER
Up-Down
ENTER
16
13- DISPLAY FUNCTIONS
ARC 1200
XR700 SPOT
ENTER
ENTER
BOOT
SYSTEM REBOOT
SYSTEM REBOOT
LAMP LIFE TIME
UNIT LIFE TIME
LAMP LIFE TIME
COUNTER RESET
SILENT
Silent operating mode during PAN&TILT movement.
By activating this function, PAN and TILT motors will
be driven with less power (during aceleration and
deceleration) in order to reduce the noise during
PAN&TILT rotation
ENTER
SILENT MODE DISABLED
ENTER
SILENT MODE ENABLED (DEFAULT)
MENU
Up-Down
ENTER
Up-Down
14- PAN & TILT SPEED (SPEE) (default: 1)
15- FAN SPEED (FANS)( default: 5)
You can set the PAN and TILT motors at high speed on your XR700 SPOT.
Press menu until you see SPEE.
Press ENTER and select a speed with UP-DOWN (there are 2 speeds). Confirm by pressing ENTER.
Fan speed regulation makes it possible to reduce fan noise. However, the ambient temperature must be
less than 35° C.
ARC 1200
XR700 SPOT
17
16- ERROR MESSAGES
ERROR: COLOR 2 WHEEL POSITION
ERROR: INTERNAL COMMUNICATION
ERROR: ENCODER PAN
ERROR: ENCODER TILT
ERROR: DMX ADDRESS
ERROR: LOAD DATA EEPROM
ERROR: EFFECTS POSITION (FROST - PRISM)
ERROR: COLOR 1 WHEEL POSITION
ERROR: FOCUS POSITION
ERROR: IRIS POSITION
ERROR: ROTATING GOBO WHEEL POSITION
ERROR: ROTATING GOBO INDEX POSITION
ERROR: FIXED GOBO WHEEL POSITION
ERROR: ZOOM POSITION
Up-DownENTER
PAN ALIGNMENT
To align pan
ENTER
Up-DownENTER
TILT ALIGNMENT
To align tilt
ENTER
Up-Down
Up-Down
ENTER
Up-DownENTERUp-Down
ROTATING GOBO WHEEL ALIGNMENT
To align the rotating gobo wheel
ENTER
Up-DownENTER
Up-Down
GOBO ROTATION ALIGNMENT
To align the gobo rotation (index)
ENTER
Up-DownENTERUp-Down
FOCUS ALIGNMENT
To align focus
ENTER
Up-DownENTERUp-Down
COLOR 1 ALIGNMENT
To align color wheel 1
ENTER
Up-DownENTERUp-Down
SHUTTER ALIGNMENT
To align shutter blades
ENTER
Up-DownENTERUp-Down
EFFECT ROTATION ALIGNMENT
To align prism on effects wheel (index)
ENTER
Up-DownENTERUp-Down
ZOOM ALIGNMENT
To align Zoom
ES.
ENTER
17- HIDDEN MENU
For technical personnel only.
To operate this menu:
-Connect the projector to the DMX controller (DMX SIGNAL MUST BE CORRECTLY RECEIVED)
- Reset the XR700 SPOT (reset from the MENU, not from the DMX controller!).
- While reset is running, press the MENU and ENTER keys at the same time.
Electronic calibration of the motors.
Reset EEPROM (Reset all settings. ATTENTION: by pressing this key you must
repeat all previous calibrations)
Exit from hidden menu.
Up-DownENTERUp-Down
FIXED GOBO WHEEL ALIGNMENT
To align the fixed gobo wheel
ENTER
Up-DownENTER
Up-Down
ES.
ENTER
Up-DownENTERUp-Down
COLOR 2 ALIGNMENT
To align color wheel 2
ENTER
ARC 1200
XR700 SPOT
18
!
Up-Down
ES.
Up-DownENTER ENTER
EFFECTS ALIGNMENT
To align the effects wheel (frost and prism)
IRIS ALIGNMENT
To align iris
19
18- OPENING THE PROJECTOR HOUSING
It is possible to inspect the inside of the projector by removing the cover as indicated below.
ATTENTION
REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR’S INTERNAL COMPONENTS.
1) Loosen the 3 screws which fix the head covers (photo 1) .
2) Once unscrewed, simply lift the covers to access the internal components (photo 2).
19- REPLACING GOBOS
XR700 SPOT uses a mechanical system which allows the fixture's gobos to be removed without the use
of special tools. Replacement gobos should be made of either heat resistant glass or metal.
An ever-increasing range of gobos is available from your DTS sales network.
Gobo dimensions are as follows:
ø external (ED) = 27.9 mm
ø of image with defined edge (ID) = 24 mm
thickness = from 0.2 to 4 mm (see catalogue)
Photo 1
Photo 2
ARC 1200
XR700 SPOT
Load with coated surface toward the light source.
Max thickness
Coated side
When an object is held up the coated side of the glass gobo there
is no space between the object and its reflection.
Uncoated side
When an object is held up the uncoated side of the glass gobo
there is a space between the object and its reflection.
Coated side
Uncoated side
ED
ID
4 mm
Replacing gobos on the rotating gobo wheel
When replacing gobos, ensure that the projector is switched off.
1) Open the projector housing as described above.
2) Remove the gobo holder to allow easier access to the gobo (photo 1).
3) Release the gobo retaining spring and carefully remove the gobo (photo 3).
4) Reverse the procedure to install a replacement gobo.
20- PERIODIC CLEANING
20.1- Lenses and reflectors
Even a fine layer of dust can reduce the luminous output substantially. Regularly clean all lenses
and the reflector using a soft cotton cloth, dampened with a specialist lens cleaning solution.
20.2- Fans and air passages
The fans and air passages must be cleaned approximately every 6 weeks. This periodic cleaning
will depend of course, on the conditions in which the projector is operating. Suitable instruments
for performing this type of maintenance are a brush and a common vacuum cleaner or an air
compressor. If necessary, clean the fans and air passages more frequently.
21- PERIODIC CONTROLS
Attention
Disconnect mains power prior to removing the projector housing.
Lamp
The lamp should be replaced if there is any visible damage or deformation due to heat. This will
help to avoid the danger of the lamp exploding.
XR700 SPOT lamp lifespan is about 750 hours, then it is necessary to replace it.
Mechanical parts
Periodically check all mechanical parts,gears, guides, belts, etc.for wear and tear, replacing them if
necessary. Periodically check the lubrication of all components, particularly the parts subject to
high temperatures. If necessary, lubricate with suitable lubricant, available from your D.T.S.
distributor. Check the tension of the belts and adjust it if necessary.
Electrical components
Check all electrical components for correct earthing and proper connection of all connectors,
refastening if necessary.
Fuse replacement
Locate the fuse, which protects the lamp and electronics, in the base of the XR700 SPOT
Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type if
necessary.
20
ARC 1200
XR700 SPOT
Photo 1
Photo 3
!
UV
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

DTS XR700 SPOT Manuale utente

Categoria
Proiettori
Tipo
Manuale utente

in altre lingue