Nikon MONARCH III Manuale utente

Categoria
Binocolo
Tipo
Manuale utente

Questo manuale è adatto anche per

Riflescope
MONARCH
Instruction manual/Bedienungsanleitung/Mode d'emploi/
Manual de instrucciones/Manuale di istruzioni
E G
S I
F
In the event that you should require service for your
Nikon RIFLESCOPE, in case of USA market, please
send it directly to:
Nikon Scope Service
841 Apollo Street, Suite 100
El Segundo, CA. 90245-4721
1-800-Nikon SV.
In other market, please bring it to dealer from which
you purchased it.
In anderen Verkaufsgebieten wenden Sie sich an den
Fachhändler, bei dem es gekauft wurde.
Pour les autres marchés, veuillez apporter la lunette de visée
au magasin où vous l'avez achetée.
En otro mercado, llévela al proveedor donde la haya adquiri-
do.
In altri mercati, portarlo presso il rivenditore dove lo si è
acquistato.
Printed in Taiwan (509B) /1E
Congratulations on your choice of a Nikon RIFLESCOPE. Your new scope is the
finest example of Nikon's rugged and durable construction and precision bright
optics; important qualities for a serious shooter's riflescope.
Whether you use your scope for hunting or for target shooting, the procedure
for mounting is identical. You should acquire a set of high quality steel mount-
ing rings which have a standard diameter of 25.4 mm (1 inch). Follow the ring
manufacturer's instructions for mounting procedures. After mounting the scope
on your rifle, follow the procedures for reticle alignment.
Caution
(1) Do not look at the sun through the riflescope. It will permanently dam-
age your eye. This precaution applies to all optical devices such as cam-
eras and binoculars.
(2) The riflescope is effectively sealed against moisture and dust. You may
use your scope safely either in the rain or in dusty climates. To preserve
the appearance of the scope, we suggest that it be dried and cleaned
prior to storage. Use a soft cloth for cleaning metal surfaces and use
photographic lens tissue to clean the scope's lenses.
When setting the reticle for hunting, you should determine your standard range
and then adjust the reticle based upon that target distance. For targets which
vary from that standard distance you may simply adjust the position of the reti-
cle in relation to your target, or you may wish to use the procedure for trajectory
compensation. It's up to your personal preference.
We hope that you will enjoy your new Nikon RIFLESCOPE for many years to
come. Enjoy using it, and above all, always follow safe shooting procedures!
The product(s) described herein may be subject to export control regulations in
the relevant country(ies). It (they) should not be exported without authorization
of the exporting govermental authority if the regulations apply.
1. Nomenclature
1. Nomenklatur
1. Nomenclature
1. Nomenclatura
1. Nomenclatura
Herzlichen Glückwunsch zum Kauf eines Nikon RIFLESCOPE. Ihr neues Zielfer-
nrohr zeichnete sich durch die robuste und haltbare Konstruktion ebenso wie
die lichtstarke Präzisionsoptik von Nikon aus; wichtige Eigenschaften für ein
hochwertiges Zielfernrohr.
Egal ob Sie das Zielfernrohr zur Jagd oder zum Scheibenschießen verwenden,
das Anbringungsverfahren ist gleich. Sie sollten einen Satz Stahlmontageringe
guter Qualität mit Standarddurchmsser von 25,4 mm besorgen. Nach de
Anbringen des Zielfernrohrs am Gewehr folgen Sie den Verfahren zur
Fadenkreuz-Ausrichtung.
Achtung
(1) Blicken Sie niemals durch das Zielfernrohr in die Sonne. Dabei besteht
die Gefahr permanenter Augenschäden. Die gleiche Vorsichtsmaßregel
gilt auch für alle anderen optischen Geräte wie Kameras und Ferngläser.
(2) Das Zielfernrohr ist wirksam gegen Feuchtigkeit und Staub abgedichtet.
Sie können das Zielfernrohr sicher sowohl im Regen als auch in
staubiger Umgebung verwenden. Um das gute Aussehen es Zielfern-
rohrs zu bewehren, raten wir, es vor der Lagerung zu trocknen und zu
reinigen. Verwenden Sie zur Reinigung von Metalloberflächen ein
weiches Tuch und zur Reinigung der Objektivlinsen sauberes Objek-
tivreinigungspapier.
Beim Einstellen des Fadenkreuzes zur Jagd sollten Sie die Standardentfernung
bestimmen und dann das Fadenkreuz basierend auf dieser Zielentfernung
justieren. Bei Zielen, die von der Standardentfernung abweichen, können Sie
dann einfach die Position des Fadenkreuzes in Beziehung zum Ziel nachstellen
oder Sie können dem Verfahren zur Flugbahnkorrektur folgen, je nach
persönlichem Geschmack.
Wir hoffen, daß Sie an Ihrem neuen Nikon RIFLESCOPE jahrelang Freude
haben. Genießen Sie es, und denken Sie daran, immer allen Sicherheitsregeln
beim Schießen zu folgen!
Für die voranstehend beschriebenen Produkte bestehen in einigen Ländern
womöglich spezielle Ausfuhrbestimmungen. Bei Zutreffen einschlägiger
Vorschriften dari das Produkt ohne vorherige Genehmigung der Außenhandels-
behörde nicht exportiert werden.
Nous vous félicitons d'avoir choisi une Nikon RIFLESCOPE. Votre nouvelle
lunette représente le plus bel exemple d'instrument d'optique de construction
solide et durable et de precision de Nikon, qualites importantes pour la lunette
de visée d'un tireur sérieux.
Que vous utilisiez votre lunette pour la chasse ou pour le tir à la cible, la
procédure de montage est la même. Vous devrez vous procurer un jeu de
bagues de montage d'acier de haute qualité d'un diamètre standard de 25,4 mm
(1 pouce). Pour le montage, suivez les instructions du fabricant des bagues.
Après avoir monté la lunette de visée sur votre fusil, réglez l'alignement du
réticule (croisée de fils) comme suit.
Précautions
(1) Ne regardez pas le soleil par la lunette de visée. Vous vous endom-
mageriez irrémédiablement la vue. Cette précaution s'applique à tous les
instruments d'optique, comme les appareils photo et les jumelles.
(2) La lunette de visée est étanche contre l'humidité et la poussière. Vous
pourrez utiliser votre lunette de visée en toute sécurité sous la pluie et
dans les environnements poussiéreux. Pour conserver l'extérieur de la
lunette en bon état, nous vous suggérons de la sécher et de la nettoyer
avant de la ranger. Utilisez un chiffon doux pour nettoyer les parties
métalliques, et utilisez des papiers pour objectif photo pour nettoyer les
lentilles de la lunette.
Pour régler le réticule pour la chasse, vous devrez tout d'abord déterminer la
portée standard, puis réglez le réticule sur la base de cette distance de cible.
Pour des cibles qui débordent de cette distance standard, vous pouvez régler
simplement la position du réticule par rapport à la cible, ou bien vous pouvez
aussi effectuer une correction de trajectoire, à votre choix.
Nous espérons que votre nouvelle Nikon RIFLESCOPE vous procurera de nom-
breuses années de divertissement. Profitez-en, mais avant tout, respectez tou-
jours les consignes de sécurité en matière de tir !
Les produils décrits ci-dessus peuvent ëtre sujets à des réglementations d'ex-
portation dans les différents pays concernés. Les produits ne peuvent étre
exportés sans l'autorisatin de l'instance officielle compétente en matière d'ex-
portations dans le cas où ces réglementations sont applicables.
Felicitaciones por haber elegido una Nikon RIFLESCOPE. Su nueva mira es el
mejor ejemplo de la brillante óptica de precisión y construcción resistente y
durable; cualidades importantes para una mira telescópica para rifles de un
tirador serio.
Ya sea que utilice su mira para la caza o para el tiro al blanco, el procedimiento
de montaje es idéntico. Usted deberá adquirir un juego de anillos de montaje
de acero de alta calidad que tenga un diámetro estándar de 25,4 mm (1 pulga-
da). Siga las instrucciones del fabricante del anillo para los procedimientos de
montaje. Después de instalar la mira en su rifle, siga los procedimientos de
alineación del retículo (en cruz).
Advertencia
(1) No mire al sol a través de la mira telescopica para rifles. Esto dañará
permanentemente su ojo. Esta precaución se aplica a todos los dis-
positivos ópticos tales como cámaras y binoculares.
(2) La mira telescópica para rifles está sellada efectivamente contra la
humedad y el polvo. Usted podrá utilizar su mira con seguridad tanto en
la lluvia como en ambientes polvorientos. Para preservar el aspecto de
la mira, sugerimos que la seque y limpie antes de guardarla. Utilice un
paño suave para limpiar las superficies de metal y pañuelos de papel
para lentes fotográficas para limpiar las lentes de la mira.
Cuando ajuste el retículo para cazar, deberá determinar el alcance estándar y
después ajustar el retículo en base con esa distancia al blanco. Para blancos
que varíen de tal distancia estándar usted podrá ajustar simplemente la posi-
ción del reticulo en relación con el blanco, o utilizar el procedimiento para la
compensación de la trayectoria. Esto depende de su preferencia personal.
Esperamos que disfrute de su nueva Nikon RIFLESCOPE durante muchos años.
!Disfrute utilizándola, y sobre todo, siempre siga los procedimientos de tiro
seguro!
Es probable que los productos aqui descritos estén sujetos a legislación para el
control de las exportactiones en determinados palses. Si dicha legislación fuera
aplicable, no deben ser exportados sin el permiso de la autoridad estatal en
materia de exportaciones.
Congratulazioni per aver scelto un Riflescope Nikon. Questo mirino è il
migliore esempio della costruzione robusta e durevole e della luminosa ottica
di precisione di Nikon, qualità importanti per il mirino dei tiratori seri.
Sia che si usi il mirino per la caccia sia per il tiro al bersaglio, il procedimento
di montaggio è identico. Procurarsi una serie di anelli di montaggio in acciaio
di buona qualità con un diametro standard di 25,4 mm. Seguire le istruzioni del
fabbricante degli anelli per i procedimenti di montaggio. Dopo aver montato il
mirino sul fucile, procedere come segue per allineare il reticolo.
Cautela
(1) Non guardare il sole attraverso il mirino. Questo causa danni permanenti
alla vista. Questa precauzione vale per tutti i dispositivi ottici come foto-
camere e binocoli.
(2) Il mirino è effettivamente sigillato come protezione da umidità e polvere.
Si può usare il mirino in sicurezza sia sotto la pioggia che in luoghi
polverosi. Per proteggere l'aspetto del mirino, consigliamo di asciugarlo
e pulirlo prima di riporlo. Usare un panno morbido per la pulizia delle
superfici metalliche e carta di pulizia per obiettivi fotografici per pulire le
lenti del mirino.
Quando si imposta il reticolo per la caccia, stabilire il proprio raggio normale e
quindi regolare il reticolo in base a quella distanza dal bersaglio. Per i bersagli
che si trovano a distanze diverse da quella normale, si può regolare semplice-
mente la posizione del reticolo in rapporto al bersaglio o si può usare il pro-
cedimento di compensazione della traiettoria, come si preferisce.
Speriamo che il Riflescope Nikon vi sarà utile per molti anni a venire. Vi
auguriamo piacere nell'usarlo e seguite sempre le modalità di sicurezza per il
tiro!
I prodotti descritti in questo catalogo sono soggetti alle normative di controllo
esportazione vigenti nel Paese di destinazione. In caso di applicazione della
suddetta regolamentazione, questi prodotti non possono essere esportati senza
preventiva autorizzazione dell'autorità governativa.
3-25, Futaba 1-chome, Shinagawa-ku, Tokyo 142-0043, Japan
Tel:+81-3-3788-7697 Fax:+81-3-3788-7698
Manufacturer:
2.5-10x42
2.5-10x50
3-12x42 SF
4-16x42 SF
5-20x44 SF
6-24x50 SF
Objective lens
Eyepiece lens
Elevation adjustment
Windage adjustment
Eyepiece adjustment
Eyepiece power index
0 (Zero) diopter point
Power index
Power scale
Power selector ring
Side focus adjustment
Distance scale
Distance index
Objektiv
Okular
Höhenverstellung
Seitenverstellung
Okulareinstellung
Okularstärkenindex
0 (Null) stäkenpunkt
Stärkenindexpunkt
Stärkenskala
Stärkenwahlring
SeitlicheräSch rte-Einstellring
Entferungsskalen
Entferungsskalen-Index
Objectif
Oculaire
Réglage d'élévation
Réglage de dérivation
Réglage d'oculaire
Oculaire d'indec de puissance
0 (Zéro) Paint de diopter
Point d'indec de puissance
Echelle de puissance
Bague de sélection de puissance
Bague de réglage de miss au point latérale
Déchelle de distance
Index de distance
Objetivo
Ocular
Dispositivo de ajuste de elevación
Dispositivo de ajuste del efecto del viento
Dispositivo de ajuste del ocular
Punto de índice de potencia del ocular
0 (Zero) Punto de diottrica
Punto de índice de potencia
Escala de potencia
Anillo seléction
Anillo de ajuste de enfoque lateral
Escala de distancias
Indice de distancias
Lente dell'obiettivo
Lente dell'oculare
Dispositivo di regolazion dellélevazione
Dispositivo di regolazion della deriva
Dispositivo di regolazion delloculare
Punto indice di delloculare
0 (Zero) punto di diottre
Punto indice di ingrandimento
Scala di ingrandimento
Anello di selezione ingrandimento
Anello laterale di messa a fuoco
Scala di distantanza
Indice di distanza
ITEM SUPPLIED
Body
.......................................................
1 piece
Eyepiece cap (flip -open)
.......................
1 piece
Objective cap (flip-open) ......
.................
1 piece
Knob & cap & Hood....................Refer to Table
Nikon cloth............................................1 piece
TEILE BEZEICHNUNG
Gehäuse
............................................
....
1 Stück
Okularkappe (aufklappbar)
....................
1 Stück
Objektivkappe (aufklappbar)
..................
1 Stück
Knopf & Kappe und Haube
..........Siehe Tabelle
Nikontuch
..............................................
1 Stück
ELEMENTS FOURNIS
Cuerpo
...................................................
1 pieza
Tapa del ocular (abierto)
........................
1 pieza
Tapa del ocular (abierto)
........................
1 pieza
Perilla et tapa et clarté du pare-soleil
...
Consulte el Cuadro
Paño de Nikon
......................................
1 pieza
ELEMENT FORNITI
Corpo
....................................................
1 pezzo
Coperchietto dell’oculare (giretto-aperto)
.......
1 pezzo
Coperchietto dell’obiettivo (giretto-aperto)
......
1 pezzo
Manopola e coperchietto y Funda
...
Riferirsi alla tabella
Tessuto Nikon ...............................................
1 pezzo
ELEMENT FORNITI
Boîtier
...................................................
1
pièce
Cache de l’oculaire (ouverture-bascule)
.......1
pièce
Cache de l’objectif (ouverture-bascule)
........1
pièce
Bouton et cache si paraluce
..............Cf. tableau
Chiffon Nikon
........................................1 pièce
2. Specifications
moa=minute of angle (In front of 100 yards 1/4 moa is nearly equal to 1/4 inches.)
Nikon riflescopes are factory set to be parallax free at 100 yds (91.44 m). 3-12x42 SF, 4-16x42 SF, 5-20x44 SF and 6-24x50 SF
allow free adjustment from 50 yds. up to infinite point.
(at minimum magnification)-(at maximum magnification)
Model 3-12x42 SF 2.5-10x42 2.5-10x50 4-16x42 SF 5-20x44 SF 6-24x50 SF
Actual Magnification
Objective Diameter (mm)
(in)
42 mm
1.65 in
3.5 mm
0.14 in
101.6-94.0 mm
4.0-3.7 in
10.2-2.6m
33.6-8.4ft
25.4 mm
1 in
49.3 mm
1.94 in
333 mm
13.11 in
530 g
18.7 oz
60
3x-12x
45.72 m
50 yards
44 mm
1.73 in
1 click = 1/4 Moa
42 mm
1.65 in
4.2 mm
0.17 in
101.6-96.5 mm
4.0-3.8 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
49.3 mm
1.94 in
319 mm
12.56 in
470 g
16.6 oz
70
2.5x-10x
91.44 m
100 yards
44 mm
1.73 in
1 click = 1/4 Moa
50 mm
1.97 in
5.0 mm
0.20 in
101.6-99.1 mm
4.0-3.9 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
57.3 mm
2.26 in
347 mm
13.66 in
510 g
18.0 oz
70
2.5x-10x
91.44 m
100 yards
44 mm
1.73 in
1 click = 1/4 Moa
42 mm
1.65 in
2.6 mm
0.10 in
101.6-94.0 mm
4.0-3.7 in
7.7-1.9m
25.2-6.3ft
25.4 mm
1 in
49.3 mm
1.94 in
344 mm
13.54 in
540 g
19.0 oz
40
4x-16x
45.72 m
50 yards
44 mm
1.73 in
1 click = 1/4 Moa
44 mm
1.73 in
2.2 mm
0.09 in
101.6-91.4 mm
4.0-3.6 in
6.1-1.5m
20.1-5.0ft
25.4 mm
1 in
52.0 mm
2.05 in
357 mm
14.06 in
540 g
19.0 oz
34
5x-20x
45.72 m
50 yards
44 mm
1.73 in
1 click = 1/8 Moa
50 mm
1.97 in
2.1 mm
0.08 in
101.6-91.4 mm
4.0-3.6 in
5.1-1.3m
16.8-4.2ft
25.4 mm
1 in
57.3 mm
2.26 in
394 mm
15.51 in
580 g
20.5 oz
30
6x-24x
45.72 m
50 yards
44 mm
1.73 in
333 mm
13.11 in
530 g
18.7 oz
60
44 mm
1.73 in
319 mm
12.56 in
470 g
16.6 oz
70
44 mm
1.73 in
347 mm
13.66 in
510 g
18.0 oz
70
44 mm
1.73 in
344 mm
13.54 in
540 g
19.0 oz
40
44 mm
1.73 in
357 mm
14.06 in
540 g
19.0 oz
34
44 mm
1.73 in
394 mm
15.51 in
580 g
20.5 oz
30
44 mm
1.73 in
333 mm
13.11 in
530 g
18.7 oz
60
44 mm
1.73 in
319 mm
12.56 in
470 g
16.6 oz
70
44 mm
1.73 in
347 mm
13.66 in
510 g
18.0 oz
70
44 mm
1.73 in
344 mm
13.54 in
540 g
19.0 oz
40
44 mm
1.73 in
357 mm
14.06 in
540 g
19.0 oz
34
44 mm
1.73 in
394 mm
15.51 in
580 g
20.5 oz
30
44 mm
1.73 in
333 mm
13.11 in
530 g
18.7 oz
60
44 mm
1.73 in
319 mm
12.56 in
470 g
16.6 oz
70
44 mm
1.73 in
347 mm
13.66 in
510 g
18.0 oz
70
44 mm
1.73 in
344 mm
13.54 in
540 g
19.0 oz
40
44 mm
1.73 in
357 mm
14.06 in
540 g
19.0 oz
34
44 mm
1.73 in
394 mm
15.51 in
580 g
20.5 oz
30
44 mm
1.73 in
333 mm
13.11 in
530 g
18.7 oz
60
44 mm
1.73 in
319 mm
12.56 in
470 g
16.6 oz
70
44 mm
1.73 in
347 mm
13.66 in
510 g
18.0 oz
70
44 mm
1.73 in
344 mm
13.54 in
540 g
19.0 oz
40
44 mm
1.73 in
357 mm
14.06 in
540 g
19.0 oz
34
44 mm
1.73 in
394 mm
15.51 in
580 g
20.5 oz
30
44 mm
1.73 in
1 click = 1/8 Moa
Exit Pupil (mm)
(in)
Eye Relief (mm)
(in)
Field of View at 100yds. (m)
(ft)
Tube Diameter (mm)
(in)
Objective Tube Dia. (mm)
(in)
Length (mm)
(in)
Weight (g)
(oz)
Adjustment Graduation
(moa)
Maximum Internal
Adjustment (moa)
(Elevation & Windage)
Parallax Setting (m)
(yds)
Outside Diameter of (mm)
Eyepiece (in)
2. Technische Daten
moa=Minute es Winkels (auf einer Entfernung von 100 Yard entspricht 1/4 moa fast 1/4 Zoll.)
Nikon-Zielfernrohre sind werkseitig parallaxenfrei auf 91,44 m (100 yards) eingestellt. 3-12x42 SF, 4-16x42 SF, 5-20x44 SF und
6-24x50 SF erlauben freie Einstellung von 45,72 m (50 yards) bis unendlich.
(bei minimaler Vergrößerung)-(bei maximaler Vergrößerung)
Model 3-12x42 SF 2.5-10x42 2.5-10x50 4-16x42 SF 5-20x44 SF 6-24x50 SF
Tatsächliche Vergrößerung
Objektivdurchmesser (mm)
(in)
42 mm
1.65 in
3.5 mm
0.14 in
101.6-94.0 mm
4.0-3.7 in
10.2-2.6m
33.6-8.4ft
25.4 mm
1 in
49.3 mm
1.94 in
3x-12x
45.72 m
50 yards
1 click = 1/4 Moa
42 mm
1.65 in
4.2 mm
0.17 in
101.6-96.5 mm
4.0-3.8 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
49.3 mm
1.94 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
50 mm
1.97 in
5.0 mm
0.20 in
101.6-99.1 mm
4.0-3.9 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
57.3 mm
2.26 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
42 mm
1.65 in
2.6 mm
0.10 in
101.6-94.0 mm
4.0-3.7 in
7.7-1.9m
25.2-6.3ft
25.4 mm
1 in
49.3 mm
1.94 in
4x-16x
45.72 m
50 yards
1 click = 1/4 Moa
44 mm
1.73 in
2.2 mm
0.09 in
101.6-91.4 mm
4.0-3.6 in
6.1-1.5m
20.1-5.0ft
25.4 mm
1 in
52.0 mm
2.05 in
5x-20x
45.72 m
50 yards
1 click = 1/8 Moa
50 mm
1.97 in
2.1 mm
0.08 in
101.6-91.4 mm
4.0-3.6 in
5.1-1.3m
16.8-4.2ft
25.4 mm
1 in
57.3 mm
2.26 in
6x-24x
45.72 m
50 yards
1 click = 1/8 Moa
Austrittspupille (mm)
(in)
Abstand der Austrittspupille (mm)
(in)
ehfeld bei 100m (m)
(ft)
Tubusdurchmesser (mm)
(in)
Objedtivtubusdurchmesser (mm)
(in)
Länge (mm)
(in)
Gewicht (g)
(oz)
Einstellteilung
(moa)
Maximale interne
Einstellung (moa)
(Höhe und Seite)
Parallaxeneinstellung (m)
(yds)
Außendurchmesser (mm)
des Okulars (in)
2. Spécifications
moa=minute d'angle (De face à 100 yards, une moa d'1/4 est à peu près équivalente à 1/4 de pouce.)
Les lunettes de visée Nikon sont réglées en usine pour être exemptes de parallaxe à 91,44 m (100 yards). Les lunettes 3-12x42
SF, 4-16x42 SF, 5-20x44 SF et 6-24x50 SF permettent un réglage libre de 45,72 m (50 yards) a l'infini.
(au grossissement minimum)-(au grossissement maximum)
Model 3-12x42 SF 2.5-10x42 2.5-10x50 4-16x42 SF 5-20x44 SF 6-24x50 SF
Grossissement réel
Diamétre d'objectif (mm)
(in)
42 mm
1.65 in
3.5 mm
0.14 in
101.6-94.0 mm
4.0-3.7 in
10.2-2.6m
33.6-8.4ft
25.4 mm
1 in
49.3 mm
1.94 in
3x-12x
45.72 m
50 yards
1 click = 1/4 Moa
42 mm
1.65 in
4.2 mm
0.17 in
101.6-96.5 mm
4.0-3.8 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
49.3 mm
1.94 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
50 mm
1.97 in
5.0 mm
0.20 in
101.6-99.1 mm
4.0-3.9 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
57.3 mm
2.26 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
42 mm
1.65 in
2.6 mm
0.10 in
101.6-94.0 mm
4.0-3.7 in
7.7-1.9m
25.2-6.3ft
25.4 mm
1 in
49.3 mm
1.94 in
4x-16x
45.72 m
50 yards
1 click = 1/4 Moa
44 mm
1.73 in
2.2 mm
0.09 in
101.6-91.4 mm
4.0-3.6 in
6.1-1.5m
20.1-5.0ft
25.4 mm
1 in
52.0 mm
2.05 in
5x-20x
45.72 m
50 yards
1 click = 1/8 Moa
50 mm
1.97 in
2.1 mm
0.08 in
101.6-91.4 mm
4.0-3.6 in
5.1-1.3m
16.8-4.2ft
25.4 mm
1 in
57.3 mm
2.26 in
6x-24x
45.72 m
50 yards
1 click = 1/8 Moa
Pupille de sortie (mm)
(in)
Dégagement oculaire (mm)
(in)
Champ linéaire perçu à 90m
(100 yards)
Diamètre de tube (mm)
(in)
Diamètre de tube d'objectif (mm)
(in)
Longueur (mm)
(in)
Poids (g)
(oz)
Graduations de règlage
(moa)
Reglage interne
maximal (moa)
(Elévation et dérivation)
Réglages de parallaxe (m)
(yds)
Diamètre extérieur d'oculaire (mm)
(in)
2. Especificaciones
moa=minutos de ángulo (En el frente de 100 yardas 1/4 moa es casi equivalente a 1/4 pulgada)
Las miras telescópicas para rifles Nikon han sido fabricadas para que no necesiten ajuste de paralaje a 100 yardas (91,44 m). 3-
12x42 SF, 4-16x42 SF, 5-20x44 SF y 6-24x50 SF pueden ajustarse libremente desde 50 yardas (45,72 m) hasta el punto infinito.
(en aumento mínimo)-(en aumento máximo)
Model 3-12x42 SF 2.5-10x42 2.5-10x50 4-16x42 SF 5-20x44 SF 6-24x50 SF
Aumento actual
Diámetro del objetivo (mm)
(in)
42 mm
1.65 in
3.5 mm
0.14 in
101.6-94.0 mm
4.0-3.7 in
10.2-2.6m
33.6-8.4ft
25.4 mm
1 in
49.3 mm
1.94 in
3x-12x
45.72 m
50 yards
1 click = 1/4 Moa
42 mm
1.65 in
4.2 mm
0.17 in
101.6-96.5 mm
4.0-3.8 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
49.3 mm
1.94 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
50 mm
1.97 in
5.0 mm
0.20 in
101.6-99.1 mm
4.0-3.9 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
57.3 mm
2.26 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
42 mm
1.65 in
2.6 mm
0.10 in
101.6-94.0 mm
4.0-3.7 in
7.7-1.9m
25.2-6.3ft
25.4 mm
1 in
49.3 mm
1.94 in
4x-16x
45.72 m
50 yards
1 click = 1/4 Moa
44 mm
1.73 in
2.2 mm
0.09 in
101.6-91.4 mm
4.0-3.6 in
6.1-1.5m
20.1-5.0ft
25.4 mm
1 in
52.0 mm
2.05 in
5x-20x
45.72 m
50 yards
1 click = 1/8 Moa
50 mm
1.97 in
2.1 mm
0.08 in
101.6-91.4 mm
4.0-3.6 in
5.1-1.3m
16.8-4.2ft
25.4 mm
1 in
57.3 mm
2.26 in
6x-24x
45.72 m
50 yards
1 click = 1/8 Moa
Pupila de salida (mm)
(in)
Distancia aprox. de la pupila de
(mm)
salida al ocular (in)
Campo de visión a 100 yardas (m)
(ft)
Diámetro del tubo (mm)
(in)
Diám. del tubo del objetivo (mm)
(in)
Longitud (mm)
(in)
Peso (g)
(oz)
Graduación de ajuste
(moa)
Ajuste interno máximo
(elevacion y efecto (moa)
del viento)
Ajustes de paralaje (m)
(yds)
Diámetro exterior del ocular (mm)
(in)
2. Dati tecnici
moa=minuto di angolo (Davanti a 100 iarde 1/4 moa è quasi uguale a 1/4 pollici.)
I mirnin Nikon sono stati impostati in fabbrica per nessun parallasse a 100 iarde (91,44 m). 3-12x42 SF, 4-16x42 SF, 5-20x44 SF
e 6-24x50 SF permettono la regolazione libera da 50 iarde (45,72 m) all'infinito.
(al minimo ingrandimento)-(al massimo ingrandimento)
Model 3-12x42 SF 2.5-10x42 2.5-10x50 4-16x42 SF 5-20x44 SF 6-24x50 SF
Ingrandimento effettivo
Diametro obiettivo (mm)
(in)
42 mm
1.65 in
3.5 mm
0.14 in
101.6-94.0 mm
4.0-3.7 in
10.2-2.6m
33.6-8.4ft
25.4 mm
1 in
49.3 mm
1.94 in
3x-12x
45.72 m
50 yards
1 click = 1/4 Moa
42 mm
1.65 in
4.2 mm
0.17 in
101.6-96.5 mm
4.0-3.8 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
49.3 mm
1.94 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
50 mm
1.97 in
5.0 mm
0.20 in
101.6-99.1 mm
4.0-3.9 in
12.3-3.1m
40.3-10.1ft
25.4 mm
1 in
57.3 mm
2.26 in
2.5x-10x
91.44 m
100 yards
1 click = 1/4 Moa
42 mm
1.65 in
2.6 mm
0.10 in
101.6-94.0 mm
4.0-3.7 in
7.7-1.9m
25.2-6.3ft
25.4 mm
1 in
49.3 mm
1.94 in
4x-16x
45.72 m
50 yards
1 click = 1/4 Moa
44 mm
1.73 in
2.2 mm
0.09 in
101.6-91.4 mm
4.0-3.6 in
6.1-1.5m
20.1-5.0ft
25.4 mm
1 in
52.0 mm
2.05 in
5x-20x
45.72 m
50 yards
1 click = 1/8 Moa
50 mm
1.97 in
2.1 mm
0.08 in
101.6-91.4 mm
4.0-3.6 in
5.1-1.3m
16.8-4.2ft
25.4 mm
1 in
57.3 mm
2.26 in
6x-24x
45.72 m
50 yards
1 click = 1/8 Moa
Pupilla di uscita (mm)
(in)
Sollievo occhio (mm)
(in)
Campo di visione a 100 iarde (m)
(ft)
Diametro canna (mm)
(in)
Diametro canna obiettivo (mm)
(in)
Lunghezza (mm)
(in)
Peso (g)
(oz)
Graduazione regolatore
(moa)
Regolazione interna
massima (moa)
(elevazione e vento)
Impostazioni di (m)
(yds)
Diametro esterno oculare (mm)
(in)
Fig. 1-1
Abb. 1-1
Fig. 1-2
Abb. 1-2
Fig. 1-4
Abb. 1-4
Fig. 1-6
Abb. 1-6
Fig. 1-3
Abb. 1-3
Fig. 1-5
Abb. 1-5
3-12x42 SF
4-16x42 SF
2.5-10x42
2.5-10x50
5-20x44 SF
6-24x50 SF
Magnified Figure of 2.5-10x42,
2.5-10x50 Hand turn Grip
Vergrößerte Darstellung des
2.5-10x42, 2.5-10x50
Handdrehgriffs
Schéma agrandi de la poignée à
rotation manuelle 2.5-10x42,
2.5-10x50
Ilustracion ampliada del cilindro de
ajuste manual 2.5-10x42,
2.5-10x50
Figura ingrandita dell'impugnatura
2.5-10x42, 2.5-10x50
a rotazione manuale
Magnified Figure of 3-12x42 SF,
4-16x42 SF Hand turn Grip
Vergrößerte Darstellung des
3-12x42 SF, 4-16x42 SF
Handdrehgriffs
Schéma agrandi de la poignée à
rotation manuelle 3-12x42 SF,
4-16x42 SF
Ilustracion ampliada del cilindro de
ajuste manual 3-12x42 SF,
4-16x42 SF
Figura ingrandita dell'impugnatura
3-12x42 SF, 4-16x42 SF
a rotazione manuale
Magnified Figure of 5-20x44 SF,
6-24x50 SF Hand turn Grip
Vergrößerte Darstellung des
5-20x44 SF, 6-24x50 SF
Handdrehgriffs
Schéma agrandi de la poignée à
rotation manuelle 5-20x44 SF,
6-24x50 SFF
Ilustracion ampliada del cilindro de
ajuste manual 5-20x44 SF,
6-24x50 SF
Figura ingrandita dell'impugnatura
5-20x44 SF, 6-24x50 SF
a rotazione manuale
Standard set
Standardsatz
Juego estándar
Equipement standard
Montaggio standard
Option
Option
Opcíon
Standard set
Standardsatz
Juego estándar
Equipement standard
Montaggio standard
Option
Option
Opcíon
Opzione
Option
Standard set
Standardsatz
Juego estándar
Standard set
Standardsatz
Juego estándar
Equipement standard
Montaggio standard
Fig. 1-7
Abb. 1-7
Fig. 1-8
Abb. 1-8
Fig. 1-9
Abb. 1-9
Fig. 1-10
Abb. 1-10
Elevation adjustment (1/4")
Höhenverstellung (1/4")
Ajuste de altura (1/4")
Réglage de la hauteur (1/4")
Regolazine dellélevazione (1/4")
Elevation adjustment (1/8")
Höhenverstellung (1/8")
Ajuste de altura (1/8")
Réglage de la hauteur (1/8")
Regolazine dellélevazione (1/8")
Windage adjustment (1/4")
Seitenverstellung (1/4")
Ajuste de bobinado (1/4")
Réglage de la déviation (1/4")
Regolazione del vento (1/4")
Windage adjustment (1/8")
Seitenverstellung (1/8")
Ajuste de bobinado (1/8")
Réglage de la déviation (1/8")
Regolazione del vento (1/8")
Opzione
Option
Equipement standard
Montaggio standard
Low profile knob
Screw for Low profile knob
Cap for Low profile knob
Target type High profile knob
Screw for Target type High profile knob
Cap for Target type High profile knob
Niedrigprofilknopf
Schraube für Niedrigprofilknopf
Kappe für Niedrigprofilknopf
Zielart Hochprofilknopf
Schraube für den Zielart Hochprofilknopf
Kappe für den Zielart Hochprofilknopf
Perilla de bajo perfil
Tornillo para perilla de bajo perfil
Tapa para perilla de bajo perfil
Perilla de alto perfil de tipo objeto
Tornillo para perilla de alto perfil de tipo objeto
Tapa para perilla de alto perfil de tipo objeto
Bouton de profil bas
Vis pour bouton profil bas
Cache pour bouton profil bas
Bouton profil haut type de cible
Vis pour bouton profil haut type de cible
Cache pour bouton profil haut type de cible
Manopola del profilo basso
Vite per la manopola del profilo basso
Coperchietto per la manopola del profilo basso
Manopola del profilo alto del tipo bersaglio
Vite per la manopola del profilo alto del tipo bersaglio
Coperchietto per la manopola del profilo alto del tipo bersaglio
Low profile knob
Screw for Low profile knob
Cap for Low profile knob
Target type High profile knob
Screw for Target type High profile knob
Cap for Target type High profile knob
Oversized high profile knob
Niedrigprofilknopf
Schraube für Niedrigprofilknopf
Kappe für Niedrigprofilknopf
Zielart Hochprofilknopf
Schraube für den Zielart Hochprofilknopf
Kappe für den Zielart Hochprofilknopf
Überdimensionaler Zielart Hochprofilknopf
Perilla de bajo perfil
Tornillo para perilla de bajo perfil
Tapa para perilla de bajo perfil
Perilla de alto perfil de tipo objeto
Tornillo para perilla de alto perfil de tipo objeto
Tapa para perilla de alto perfil de tipo objeto
Perilla de alto perfil de sobretamaño
Bouton de profil bas
Vis pour bouton profil bas
Cache pour bouton profil bas
Bouton profil haut type de cible
Vis pour bouton profil haut type de cible
Cache pour bouton profil haut type de cible
Bouton profil haut surdimensionné
Manopola del profilo basso
Vite per la manopola del profilo basso
Coperchietto per la manopola del profilo basso
Manopola del profilo alto del tipo bersaglio
Vite per la manopola del profilo alto del tipo bersaglio
Coperchietto per la manopola del profilo alto del tipo bersaglio
Manopola del profilo alto in dimensione ingrandita
2.5-10x42 (1/4")
2.5-10x50 (1/4")
3-12x42 SF (1/4")
4-16x42 SF (1/4")
5-20x44 SF (1/8")
6-24x50 SF (1/8")
Windage and elevation adjustment knob
Low profile knob
& cap & screw
(2 pcs.)
Target type high
profile knob & cap
Oversized
high profile knob
Screw for
high profile knob
Hood
attached
attached
attached
attached
attached
attached
option*
option*
option*
option*
included*
included*
not available
not available
not available
not available
included*
included*
option (2 pcs.)
option (2 pcs.)
option (2 pcs.)
option (2 pcs.)
included (4 pcs.)
included (4 pcs.)
option
option
option
option
included
included
*For Elevation & Windage
2.5-10x42 (1/4")
2.5-10x50 (1/4")
3-12x42 SF (1/4")
4-16x42 SF (1/4")
5-20x44 SF (1/8")
6-24x50 SF (1/8")
Einstellknöpfe für Höhen- und Seitenverstellungen
Niedrigprofilknopf &
Kappe & Schraube
(2 Stk.)
Zielart, Hochprofilknopf
& Kappe
Überdimensionaler
Hochprofilknopf
Schraube für
Hochprofilknopf
Haube
angebracht
angebracht
angebracht
angebracht
angebracht
angebracht
option*
option*
option*
option*
enthalten*
enthalten*
nicht erhältlich
nicht erhältlich
nicht erhältlich
nicht erhältlich
enthalten*
enthalten*
option (2 Stk.)
option (2 Stk.)
option (2 Stk.)
option (2 Stk.)
enthalten (4 Stk.)
enthalten (4 Stk.)
option
option
option
option
enthalten
enthalten
*für Höhen- und Seitenverstellungen
2.5-10x42 (1/4")
2.5-10x50 (1/4")
3-12x42 SF (1/4")
4-16x42 SF (1/4")
5-20x44 SF (1/8")
6-24x50 SF (1/8")
Bobinado y perilla de ajuste de altura
Perilla de bajo perfil y
tapa y tornillo
(2 pzas.)
Tapa y perilla de alto
perfil de tipo objeto
Perilla de alto perfil de
sobretamaño
Tornillo para perilla
de alto perfil
Funda
instalado
instalado
instalado
instalado
instalado
instalado
opción*
opción*
opción*
opción*
incluido*
incluido*
No existe
No existe
No existe
No existe
incluido*
incluido*
opción (2 pzas.)
opción (2 pzas.)
opción (2 pzas.)
opción (2 pzas.)
incluido (4 pzas.)
incluido (4 pzas.)
opción
opción
opción
opción
incluido
incluido
*Para altura y bobinado
2.5-10x42 (1/4")
2.5-10x50 (1/4")
3-12x42 SF (1/4")
4-16x42 SF (1/4")
5-20x44 SF (1/8")
6-24x50 SF (1/8")
Manopola di regolazione del vento e dell’elevazione
Manopola del profilo
basso, coperchietto e
vite (2 pezzi)
Manopola del profilo
alto del tipo bersaglio e
coperchietto
Manopola del profilo alto
in dimensione ingrandita
Vite per la manopola
del profilo alto
Paraluce
Incorporata
Incorporata
Incorporata
Incorporata
Incorporata
Incorporata
Opzione*
Opzione*
Opzione*
Opzione*
Inclusa*
Inclusa*
Non disponibile
Non disponibile
Non disponibile
Non disponibile
Inclusa*
Inclusa*
Opzione (2 pezzi.)
Opzione (2 pezzi.)
Opzione (2 pezzi.)
Opzione (2 pezzi.)
Inclusa (4 pezzi.)
Inclusa (4 pezzi.)
Opzione
Opzione
Opzione
Opzione
Inclusa
Inclusa
*Per l’elevazione e il vento
2.5-10x42 (1/4")
2.5-10x50 (1/4")
3-12x42 SF (1/4")
4-16x42 SF (1/4")
5-20x44 SF (1/8")
6-24x50 SF (1/8")
Bouton de réglage de déviation et de hauteur
Bouton profil bas &
cache & vis
(2 pièces)
Bouton profil haut type
de cible & cache
Bouton profil haut
surdimensionné
Vis pour bouton
profil haut
Pare-soleil
Joint
Joint
Joint
Joint
Joint
Joint
option*
option*
option*
option*
Inclus*
Inclus*
Non disponible
Non disponible
Non disponible
Non disponible
Inclus*
Inclus*
option (2 pièces)
option (2 pièces)
option (2 pièces)
option (2 pièces)
Inclus (4 pièces)
Inclus (4 pièces)
option
option
option
option
IInclus
Inclus
*Pour la hauteur et la déviation
3. Instructions
(1) Focusing
(1) Look through the eyepiece with your eye positioned about 10cm (4 in)
away from the eyepiece lens (Fig. 3-1), and you will see the Nikoplex
reticle (Fig. 3-2), the BDC reticle (Fig. 3-3) or the Miliradian Dot reticle
(Fig. 3-4) or the Crosshair reticle (Fig. 3-5) or the Crosshair with Dot
reticle (Fig. 3-6).
(1) Be sure your eye is positioned within proper alignment and proper eye
relief otherwise the view will "black out".
(1) Point the objective end of the scope at the sky (Do not point at the sun)
or at a plain unpatterned wall.
(1) Turn the eyepiece adjustment counter-clockwise and then turn it clock-
wise until the reticle appears sharp.
(1) Use the 0 (zero) diopter point and Eyepiece power index for your eye
power reference. (Fig. 3-7)
(2) Magnification
(1) The Riflescope 3-12x42 SF has a variable magnification from 3 to 12x,
2.5-10x42 and 2.5-10x50 from 2.5 to 10x, 4-16x42 SF from 4 to 16x, 5-
20x44 SF from 5 to 20x, 6-24x50 SF from 6 to 24x.
(1) To change powers. just rotate the power selector ring until the desired
magnification appears adjacent to the power index dot.
(3) Adjustment of the riflescope
(1) Sighting through the riflescope. align the rifle with your aiming point on the
target and shoot a trial round. If the bullet does not hit the aiming point,
adjust the elevation and windage. as follows:
(1) If the bullet hits under the aiming point, turn the elevation adjustment
(counter-clockwise) in the direction of the arrow marked "U" for up as in
Fig. 3-8. If the bullet hits high, turn adjustment (clockwise) in the direc-
tion of the arrow marked "D" for down.
(1) If the bullet hits to the right of the aiming point, turn the windage adjust-
ment (clockwise) in the direction of the arrow marked "L" for left as in
Fig. 3-9. If the bullet hits to the left of the aiming point, turn adjustment
(counter-clockwise) in the direction of the arrow marked "R" for right.
(1) For ther High profile knob adjustment is made by turning the knob by
hand. If the bullet hits under the aiming point, turn the knob in the direc-
tion of the arrow marked "U" (Fig. 3-10). If the bullet hits to the left of the
aiming point, turn the knob in the direction of the arrow marked "R" (Fig.
3-11).
(4) Adjustable objective
(3) The Nikon Riflescope, 3-12x42 SF, 4-16x42 SF, 5-20x44 SF, 6-24x50 SF
can be more precisely focused within the range of at least 50 yards (45.72m)
~infinity by rotating the objective adjusting ring.
(3) Parallax can be eliminated and sight alignment will be accurate.
(3) Use its distance scale as a reference guide.
(3) The adjusting ring has a lock system, so that it will not move during shoot-
ing. When adjusting the focus, pull out the adjusting ring. For lock push in
the adjusting ring. (Fig.3-12)
(5) Changing the knob (5-20x44 SF and 6-24x50 SF are supplied,
another scope are option)
(3) Remove the protective cap of the knob by turning it counterclockwise. Align
the knob to the 0 (zero) position of the scale ring. This is to assure that the
scale ring will be correctly aligned to the new knob (the alignment position
should be remembered).
(3) With the knob held with your fingers to avoid shifting of the aligned scale
ring, turn the screw in the top of the knob counterclockwise with coin until
the screw comes out (Fig. 3-13). Then remove the knob.
(3) Insert the new knob into position and align the scale ring to 0.
(3) Insert the screw. By securing the knob with your fingers to avoid shifting of
the scale ring, turn the screw clockwise with the coin, until the knob in
firmly secured.
(6) Zero setting of knob (Fig. 3-14)
(3) After the reticle has been adjusted to the point of impacts, with the knob
held with your fingers to avoid shifting of the aligned knob, turn the knob
screw in top of the knob counterclockwise with the coin. Then lift the knob
up and align the " " with the index mark. It may happen that the " "
could not align with the index mark exactly because of the coupling pitch of
the knob with the shaft. And by securing the knob with your fingers to avoid
shifting of the knob, turn the grip screw clockwise with the coin until the
knob in firmly secured.
Note:
The windage and elevation scales of the Nikon Riflescope 3-12x42 SF, 2.5-
10x42, 2.5-10x50 and 4-16x42 SF are calibrated in division of 1/4 minute of
angle with a click at intervals of 1/4 minute of angle (one division).
The windage and elevation scales of the Nikon Riflescope 5-20x44 SF and 6-
24x50 SF are calibrated in division of 1/8 minute of angle with a click at
intervals of 1/8 minute of angle (one division).
When adjusting the reticle to the point of aim, remember that one minute of
angle equals approximately one inch (2.54 cm) at 100 yards (91.44 m).
Therefore, if the impact point is two inches (5.08 cm) low and one inch (2.54
cm) right at 100 yds (91.44 m) Parallax Setting, you should adjust two min-
utes of angle up one minute of angle left. In case of 50 yds (45.72 m). Paral-
lax Setting the adjusting value is double. In case of 75 yds (68.58 m) Paral-
lax Setting is 1.5 times.
Maintenance
(1) Lens cleaning
(1) To remove dirt or fingerprint, soak gauze or lens cleaning paper (silicon-
free paper sold at camera shop) with a small quantity of absolute alcohol
(available from drugstore) and lightly wipe off. Wiping with handkerchief of
leather is not recommended as it is likely to damage the lens surface.
(1) Dust may scratch the lens surface or corrode the lens.
(1) Brush dust off using a soft oil-free brush.
(2) Scope Exterior
(1) Use a soft dry cloth to wipe off any dirt or finger-prints that might accumu-
late.
(1) It is not necessary to oil the scope's surface.
(3) Windage/Elevation Adjustments
(1) These adjustments are permanently lubricated. Do not attempt to lubricate
them. Cover with caps supplied, except when adjusting, to keep out dust
and dirt.
(4) Eyepiece Ajustment
(1) This adjustment is permanently lubricated. Do not attempt to lubricate.
(5) Power Selector Ring
(1) No lubrication is required on the power selector ring.
(1) Do not loosen or remove screws in power selector ring.
3. Anleitung
(1) Scharfstellung
(1) Durch das Okular blicken, wobei das Auge etwa 10 cm von der Okular-
linse entfernt sein soll (Abb. 3-1), und das Nikoplex Fadenkreuz (Abb. 3-
2), das mit BDC Fadenkreuz (Abb. 3-3), oder das Milliradian-Fadenkreuz
(Abb. 3-4), oder das Fadenkreuz-Absehe (Abb. 3-5) oder das Fadenkreuz
mit Punkt (Abb. 3-6) wird sichtbar.
(1) Sicherstellen, daß Ihr Auge richtig positioniert ist und für richtigen
Abstand der Austrittspupille gesorgt ist, weil andernfalls das Bild "aus-
geschwärzt" wird.
(1) Das Objektivende in den Himmel richten. (Auf keinen Fall in die Sonne)
oder auf eine gleichmäßige Wand ohne Muster.
(1) Den Okulareinstellring zuerst gegen den Uhrzeigersinn und dann im
Uhrzeigersinn drehen, bis das Fadenkreuz scharf erscheint.
(1) Verwenden Sie den 0 (Null) Dioptrienpunkt und den Brechungsindex des
Okulars als Bezugswerte für Ihre Sehstärke (Abb. 3-7)
(2) Vergrößerung
(1) Das Nikon Riflescope 3-12-42 SF hat eine Vergrößerung von 3 bis 12x
2.5-10x42 und 2.5-10x50 von 2.5 bis 10x. 4-16x42 SF von 4 bis 16x,
5-20x44 SF von 4 bis 16x, 5-20x44 SF von 5 bis 20x 6-24x50 SF von 6
bis 24x.
(1) Zum Ändern der Stärke einfach den Stärkenwahlring drehen, bis die
gewünschte Vergrößerung neben dem Stärkenin- dexpunkt erscheint.
(3) Einstellung des Zielfernrohrs
(1) Durch das Zielfernrohr blicken und das Gewehr mit dem Zielpunkt ausricht-
en und einen Probeschuß machen. Wenn die Kugel nicht das Ziel trifft, die
Höhen- und Seiteneinstellung korrigieren, wie folgt:
(1) Wenn die Kugel unter den Zielpunkt trifft, die Höheneinstellung in Pfeil-
richtung "U" drehen (gegen den Uhrzeigersinn), wie in Abbildung 3-8
gezeigt. Wenn die Kugel über den Zielpunkt trifft, die Höheneinstellung
in Pfeilrichtung "D" drehen (im Uhrzeigersinn).
(1) Wenn die Kugel rechts vom Zielpunkt trifft, die Seiteneinste- llung in
Pfeilrichtung "L" (im Uhrzeigersinn) drehen, wie in Abbildung 3-9
gezeigt. Wenn die Kugel links vom Zielpunkt trifft, die Seiteneinstellung
in Pfeilrichtung "R" (gegen den Uhrzeigersinn) drehen.
(1) Für das hoch prófil Knauf außerdem wird die Einstellung der Höhe mit
dem Höheneinstellknauf vorgenommen, indem dieser Knauf von Hand
gedreht wird. Wenn die Kugel dem Zielpunkt trifft, den Knauf in Pfeil-
richtung "U" (Abb.3-10) drehen. Wenn die Kugel links vom Zielpunkt
trifft, den Knauf in Pfeilrichtung "R" (Abb. 3-11) drehen.
(4) Einstellbares Objektiv
(3) Das Nikon Riflescope, 3-12x42 SF, 4-16x42 SF 5-20x44 SF, 6-24x50 SF
kann präziser in einem Bereich von mindestens 45,72 m (50 yards) bis
unendlich durch Drehen des Objektiveinstellrings scharfge- stellt werden.
(3) Die Parallaxe kann eliminiert werden, und die Sichtaus- richtung wird akku-
rat.
(3) Der Einstellring ist mit einem Verriegelungssystem versehen, so dass er
sich beim Schießen nicht bewegt. Den Einstellring zur Scharfstellung her-
ausziehen. Zur Verriegelung den Ring wieder hineindrücken (Abb. 3-12)
(5) Knauf auswechseln (5-20x44 SF und 6-24x50 SF werden mit-
geliefert; andere Fernrohre sind Optional)
(3) Die Schutzkappe des knauf durch Drehen gegen den Uhrzeigersinn entfer-
nen. Den knauf auf 0 (Null) Stellung auf dem Skalenring einstellen. Dies
soll sicherstellen, daß der Skalenring richtig auf den neuen knauf aus-
gerichtet ist (die Ausrichtposition sollte man sich merken).
(3) Den knauf mit den Fingern halten, um verschieben des ausgerichteten
Skalenrings zu vermeiden, die Schraube oben im knauf gegen den
Uhrzeigersinn mit dem mitgelie- ferten Sechskantschlüssel drehen, bis die
Schraube herauskommt. Dann den knauf (Abb. 3-13) entfernen.
(3) Die Schraube einsetzen. Durch Festhalten des knauf mit den Fingern, um
Verschieben des Skalenrings zu vermeiden, die Schraube mit der coin im
Uhrzeigersinn drehen, bis der knauf sicher befestigt ist.
(6) Nullstellung des knauf (Abb. 3-14)
(3) Wenn das Zielkreuz auf den Einschlagpunkt eingestellt ist, wobei der knauf
mit den Fingern gehalten wird, um Verschiebung des ausgerichteten Griffs
zu vermeiden, die knauf schraube oben auf dem knauf mit einer der Münze
gegen den Uhrzeigersinn drehen. Dann den knauf hochheben und die
Markierung " " mit der Indexmarkierng ausrichten. Es kann vorkommen,
daß " " nicht genau mit der Indexmarkierung ausgerichtet wird, aufgrund
der Kopplung des knauf mit der Welle. Durch Festhalten des knauf mit den
Fingern, um Verschieben des knauf zu vermeiden, die Griffschraube im
Uhrzeigersinn mit der Münze drehen, bis der knauf sicher befestigt ist.
Hinweis:
Die Seiteneinstellungs-und Höheneinstellungsskalen des Nikon Riflescope
3-12x42 SF, 2.5-10x42, 2.5-10x50 und 4-16x42 SF sind in Unterteilungen
von 1/4 Minute des Winkels mit einem Klick bei Intervallen von 1/4 Minute
des Winkels (eine Teilung) kalibriert.
Die Seiteneinstellungs-und Höheneinstellungs- Skalen Nikon Riflescope 5-
20x44 SF und 6-24x50 SF sind in Unterteilungen von 1/8 Minuten des
Winkels mit einem Klick bei Intervallen von 1/8 Minute des Winkels (eine
Teilung) kalibriert.
Beim Einstellen des Fadenkreuzes auf den Zielpunkt beachten Sie, daß eine
Winkelminute etwa 2,54 cm (1 inch) bei 91.44 m (100 yds) entspricht. Wenn
der Einschlagpunkt darum 5,08 cm (2 inches) zu niedrig und 2,54 cm (1
inch) rechts bei 91.44 m (100 yds) Parallaxeneinstellung ist, sollten sie zwei
Winkelminuten hoch und eine Winkelminute links zielen. Bei 45,72 m (50
yds) ist der Einstellwert für die Parallaxeneinstellung das Doppelte. Bei
68,58 m (75 yds) ist die Parallaxeneistellung das 1,5fache.
Instandhaltung
(1) Reinigung der Objektivgläser
(1) Schmutz oder Fingerabdrücke mit einem weichen Baumwolltuch oder mit
hochwertigem, siliziumfreien Objektivreinigungspapier (im Fachhandel
erhältlich) entfernen, das mit ein wenig reinem Alkohol (in Drogerien
erhältlich) abwischen. Keine Samttücher oder normales Papier verwenden,
da diese Kratzer auf dem Objektivglas hinterlassen.
(1) Staub auf dem Objektivglas mit einem weichen fettfreien Pinsel entfernen.
(2) Gehäuse
(1) Die Gehäuseoberfläche mit einem weichen, sauberen Tuch sauberwischen.
(1) Ölen der Gehäuseoberfläche ist nicht erforderlich.
(3) Seiten-/Höhen-Einstellung
(1) Diese Einstellungen sind permanent geschmiert. Nicht versuchen, sie
zusätzlich zu schmieren. Normalerweise mit den mitgelieferten Kappen
abdecken, und die Kappen nur zur Einstellung entfernen, um Schmutz und
Staub fernzuhalten.
(4) Okulareinstellung
(1) Diese Einstellung ist permanent geschmiert. Nicht versuchen, sie zusätzlich
zu schmieren.
(5) Stärkenwahlring
(1) Schmierung des Stärkenwahlrings ist nicht erforderlich. Nicht Schrauben
am Stärkenwahlring lösen oder entfernen.
3. Utilisation
(1) Mise au point
(1) Regardez dans l’oculaire, l’œil étant placé à environ 10 cm (4 pouces) de
la lentille d’oculaire (Fig. 3-1) et vous verrez le réticule Nikoplex (Fig. 3-
2), ou le réticule à BDC (Fig. 3-3) ou le réticle à point Miliradia (Fig. 3-
4), ou le réticule à croisée de fils (Fig. 3-5) ou le réticule à croisée de fils
avec point (Fig. 3-6).
(1) Veillez bien à placer l'œil dans la ligne d'alignement et avec le dégage-
ment oculaire corrects, sinon vous ne verrez rien.
(1) Dirigez l'extrémité objectif de la lunette vers le ciel (ne regardez pas le
soleil) ou sur un mur lisse et sans motifs.
(1) Tournez le réglage d'oculaire dans le sens inverse des aiguilles d'une
montre puis dans le sens des aiguilles d'une montre jusqu'à ce que le
réticule soit net.
(1) Veuillez utiliser le point de dioptrie 0 (zéro) et l’indice de puissance de
l’Oculaire en tant que référence pour votre puissance optique. (Fig.3-7)
(2) Grossissement
(1) La Nikon Riflescipe 3-12x42 SF a un rappart de grossissment variable gui
va de 3 à 12 la lunette 2.5-10x42 et 2.5-10x50 de 2.5 à 10x, la lunette 4-
16x42 SF de 4 à 16x, la lunette 5-20x44 SF de 5 à 20x, la lunette 6-24x50
SF de 6 à 24x.
(1) Pour changer la puissance, il suffit de tourner la bague de sélection de
puissance jusqu'à ce que le rapport de grossissement voulu arrive à côté
du point d'index de puissance.
(3) Réglage de la lunette de visée
(1) Tout en regardant dans la lunette, alignez le fusil sur le point de visée de la
cible et effectuez un tir d'essai. Si la balle ne touche pas le point de visée,
réglez l'élévation et la dérivation de la manière suivante :
(1) Si la balle frappe juste en-dessous du point de visée, tournez le réglage
d'élévation (sens inverse des aiguilles d'une montre) dans le sens de la
flèche marquée "U" pour relever la lunette, comme indiqué à la Fig. 3-8.
Si la balle frappe trop haut, tournez le réglage (sens des aiguilles d'une
montre) dans le sens de la flèche marquée "D" pour baisser la lunette.
(1) Si la balle frappe à droite du point de visée, tournez le réglage de dériva-
tion (sens des aiguilles d'une montre) dans le sens de la flèche marquée
"L" pour déplacer vers la gauche, comme indiqué à la Fig. 3-9. Si la
balle frappe à gauche du point de visée, tournez le réglage (sens inverse
des aiguilles d'une montre) dans le sens de la flèche marquée "R" pour
déplacer vers la droite.
(1) Avec les réglage du bouton de Profile Haut également s’effectue en tour-
nant le bouton à la main. Si la balle frappe sous le point de visée, tourn-
er le bouton dans le sens de la flèche marquée «U» (Fig. 3-10). Si la
balle frappe à gauche du point de visée, tourner le bouton dans le sens
de la flèche marquée «R» (Fig. 3-11).
(4) Objectif réglable
(3) Les Nikon Riflescope, 3-12x42 SF, 4-16x42 SF, 5-20x44 SF, 6-24x50 SF
peuvent être réglées avec une plus grande précision dans la plage de 45,72
m (50 yards) à l'infini. Pour cela, tournez la bague de réglage d'objectif.
(3) Il est possible de supprimer la parallaxe pour que l'alignement de visée soit
précis.
(3) La bague de réglage est équipée d’un système de verrouillage afin de ne pas
bouger lors du tir. Lorsque vous effectuez la mise au point, veuillez dégager
la bague de réglage. Pour le verrouillage, veuillez engager la bague de
réglage. (Fig.3-12)
(5) Remplacement du bouton (5-20x44 SF et 6-24x50 SF sont fourn-
ies, autres portées en option).
(3) Retirez le capuchon protecteur de la perilla en le tournant dans le sens
inverse des aiguilles d'une montre. Alignez la perilla sur la position 0 (zéro)
de la bague d'échelle. Ceci a pour but de garantir que la bague d'échelle
sera correctement alignée sur la nouvelle perilla (il faudra noter la position
d'alignement de façon à ne pas l'oublier).
(3) Tout en tenant la perilla avec les doigts pour éviter que la bague d'échelle
alignée ne se décale, tournez le écrou sur le dessus de la poignée dans le
sens inverse des aiguilles d'une montre à l'aide de la clé hexagonale
fournie, jusqu'à ce que le écrou ressorte. Puis, retirez la perilla (Fig. 3-13).
(3) Insérer la nouvelle perilla en place et alignez la bague d'échelle sur
0.Insérez le écrou. Tout en tenant la perilla avec les doigts pour éviter que
la bague d'échelle ne se décale, tournez le mannaie le sens des aiguilles
d'une montre à l'aide de la clé hexagonale fournie, jusqu'à ce que la perilla
soit solidement fixée.
(6) Réglage de la peria à zéro (Fig. 3-14)
(3) Une fois que le réticule a été réglé au point d'impact, tout en tenant la peril-
la avec les doigts pour éviter que la perilla perilla ne se décale, tournez la
vis de la perilla sur le dessus de la perilla dans le sens inverse des aiguilles
d'une montre avec une pièce de monnaie. Puis, soulevez la perilla et
alignez le repère " " sur le repère d'index. Il peut arriver que vous ne
puissiez aligner le repère " " exactement sur le repère d'index à cause du
pas de couplage de la perilla avec l'axe. Puis, en immobilisant la perilla
avec les doigts pour éviter qu'elle ne se décale, tournez la vis de la perilla
dans le sens des aiguilles d'une montre avec une pièce de monnaie jusqu'à
ce que la perilla soit solidement fixée.
Remarques:
Les échelles de dérivation et d'élévation des Nikon Riflescope 3-12x42 SF,
2.5-10x42, 2.5-10x50 et 4-16x42 SF sont étalonnées par divisions d'un-
quart de minute d'angle avec un cran à intervalle de 1/4 de minute d'angle
(une division).
Les échellés de dérivation et d'élévation de la Nikon Riflescope 5-20x44 SF
et 6-24x50 SF sont étalonnées par divisions d'un-huitième de minute d'an-
gle avec un cran à intervalle de 1/8ème de minute d'angle (une division).
Lorsque vous réglez le réticule sur le point de visée, n'oubliez pas qu'une
minute d'angle équivaut à peu prés à 2,54 cm (1 pouce) à 91,44 m (100
yards). En conséquence, si le point d'impact se trouve 5,08 cm (2 pouces)
trop bas et 2,54 cm (1 pouce) trop à droite d'un réglage de parallaxe de
91,44 m (100 yards), vous devrez régler deux minutes d'angle plus une
minute d'angle à gauche. Avec un réglage de parallaxe de 45,72 m (50
yards), la valeur de réglage sera double. Avec un réglage de parallaxe de
68,58 m (75 yards), il faudra multiplier par 1,5.
Entretien
(1) Nettoyage de la lentille
(1) Pour retirer les traces de doigt, imbibez une gaze de papier pour nettoyage
d'objectif (papier sans silicone vendu dans les magasins d'appareils photo)
d'une petite quantité d'alcool absolu (en vente dans les drogueries) et
essuyez légèrement. Il n'est pas recommandé d'essuyer avec un chiffon en
cuir, car cela risquerait d'endommager la surface de la lentille.
(1) La poussière peut rayer la surface de la lentille ou attaquer la lentille. Souf-
flez la poussière avec une brosse douce sans graisse.
(2) Surface exterieure de la lunette
(1) Utilisez un chiffon doux et sec pour enlever la poussière et les traces de
doigt.
(1) Il n'est pas nécessaire de graisser la surface de la lunette.
(3) Réglages de dérivation/élévation
(1) Ces réglages possèdent un système de graissage permanent. N'essayez pas
de les graisser. Recouvrez-les avec les capuchons fournis, sauf lors des
réglages, pour les protéger de la poussière et de la saleté.
(4) Réglage de l'oculaire
(1) Ce réglage possède un système de graissage permanent. N'essayez pas de
le graisser.
(5) Bague de sélection de puissance
(1) Il n'est pas nécessaire de graisser la bague de sélection de puissance. Ne
desserrez pas et ne retirez pas les vis de la bague de sélection de puis-
sance.
3. Instrucciones
(1) Enfoque
(1) Mire a través del ocular situando el ojo a 10 cm (4 pulgadas) de la lente
del ocular (Fig. 3-1), y verá el retículo Nikoplex (Fig. 3-2), la o el retic-
ule BDC (Fig. 3-3) o el retículo de punto Miliradian (Fig. 3-4), o el
retículo de cruz filial (Fig. 3-5) o el retículo o el cruz filial con retículo de
punto (Fig. 3-6).
(1) Asegúrese de que su ojo esté en alineación adecuada y a una distancia
aproximada de la pupila de salida al ocular apropiada, de lo contrario
verá un "oscurecimiento total".
(1) Apunte la parte del objetivo de la mira hacia el cielo (No apunte hacia el
sol) o hacia una pared lisa.
(1) Afloje el anillo de bloqueo. (sólo 2x20)
(1) Gire el dispositivo de ajuste del ocular en sentido contrario al de las
agujas del reloj y después gírelo en el sentido de las agujas del reloj
hasta que el retículo aparezca nítidamente.
(1) Utilice el punto de dioptría 0 (cero) y el índice de potencia del ocular
para su referencia de potencia de ojo (Fig. 3-7)
(2) Aumento
(1) La Nikon Riflescope 3-12x42 SF posse un aument variable de 3 a 12x,
2.5-10x42 de 2.5-10x50 de 2.5 a 10x, 4-16x42 SF de 4 a 16x, 5-20x44
SF de 5 a 20x, 6-24x50 SF de 6 a 24x.
(1) Para cambiar la potencia, simplemente gire el anillo selector de potencia
hasta que aparezca el aumento deseado adyacente al punto índice de
potencia.
(3) Ajuste de la mira telescópica para rifles
(1) Observando a través de la mira telescópica para rifles, alinee el rifle con el
punto de puntería en el blanco y dispare un tiro de prueba. Si la bala no
acierta el punto de puntería, ajuste la elevación y el efecto del viento, como
sigue:
(1) Si la bala acierta debajo del punto de puntería, gire el dispositivo de
ajuste de elevación (sentido contrario al de las agujas del reloj) en el
sentido de la flecha marcada con la "U" para elevar como en la Fig. 3-8.
Si la bala acierta arriba, gire el dispositivo de ajuste (en el sentido de las
agujas del reloj) en el sentido de la flecha marcada con la "D" para bajar.
(1) Si la bala acierta a la derecha del punto de puntería, gire el dispositivo de
ajuste del efecto del viento (en el sentido de las agujas del reloj) en el
sentido de la flecha marcada con la "L" para la izquierda como en la Fig.
3-9. Si la bala acierta a la izquierda del punto de puntería, gire el disposi-
tivo de ajuste (sentido contrario al de las agujas del reloj) en e l sentido
de la flecha marcada con la "R" para la derecha.
(1) Para la ajuste de la perilla de Perfil Alto se hace girando la perilla a
mano. Si la bala acierta debajo del punto de puntería, gire la perilla en el
sentido de la flecha marcada con la "U" (Fig. 3-10). Si la bala acierta a la
izquierda del punto de puntería, gire la perilla en el sentido de la flecha
marcada con la "R" (Fig. 3-11).
(4) Objetivo ajustable
(3) La Nikon Riflescope, 3-12x42 SF, 4-16x42 SF, 5-20x44 SF, 6-24x50 SF
puede enfocarse con más precisión dentro del margen de por lo menos 50
yardas (45,72 m) al infinito girando el anillo de ajuste del objetivo.
(3) El paralaje puede eliminarse y la alineación de la puntería será más exacta.
(3) Utilice la escala de distancias como guía de referencia.
(3) El anillo de ajuste tiene un sistema de bloqueo para que no se mueva
durante el disparo. Cuando ajuste el enfoque saque el anillo de ajuste. Para
bloquear, empuje el anillo de ajuste. (Fig. 3-12)
(5) Cambio de la perilla (se entregan 5-20x44 SF y 6-24x50 SF, otras
telescópicas son opcionales).
(3) Quite la tapa protectora del monopola girándola en el sentido contrario al
de las agujas del reloj. Alinee el monopola a la posición 0 (cero) del anillo
de escala. Esto es para asegurar que el anillo de escala quede correcta-
mente alineado con el monopola nuevo (deberá recordar la posición de
alineación).
(3) Sujetando el Tornillo con los dedos para evitar que se desplace el anillo de
escala, gire el perno en la parte superior del Tornillo en el sentido contrario
al de las agujas del reloj con la llave hexagonal suministrada hasta quitar el
perno. Después quite el monopola (Fig. 3-13).
(3) Inserte el Tornillo nuevo en su posición y alinee el anillo de escala a 0.
(3) Inserte el perno. Asegurando el Tornillo con los dedos para evitar que se
desplace anillo de escala, gire el perno en el sentido de las agujas del reloj
con la monede hasta que el Tornillo quede asegurado firmemente.
(6) Ajuste del cero del monopola (Fig. 3-14)
(3) Después de ajustar el retículo al punto de impactos, sosteniendo el
monopola con los dedos para evitar que se desplace el monopola alineado,
gire el tornillo del monopola en la parte superior del monopola en el senti-
do contrario al de las agujas del reloj con una moneda. Después levante el
monopola y alinee " " con la marca de índice. Puede ocurrir que " " no
pueda alinearse exactamente con la marca de índice debido a la altura de
acoplamiento del monopola con el eje. Y asegurando el monopola con los
dedos para evitar que se desplace, gire el tornillo en el sentido de las agu-
jas del reloj con una moneda hasta que el monopola quede asegurado
firmemente.
Nota:
Las escalas del dispositivo de ajuste del efecto del viento y la elevación de la
Nikon Riflescope 3-12x42 SF, 2.5-10x42, 2.5-10x50 y 4-16x42 SF están
calibradas en divisiones de 1/4 minuto de ángulo con un clic a intervalos de
1/4 minuto de ángulo (una division).
Las escalas del dispositivo de ajuste del efecto del viento y la elevación de la
Nikon Riflescope 5-20x44 SF y 6-24x50 SF están calibradas en divisiones
de 1/8 minuto de ángulo con un clic a intervalos de 1/8 minuto de ángulo
(una división).
Cuando ajuste el retículo al punto de puntería, recuerde que un minuto de
ángulo equivale aproximadamente 2,54 cm (una pulgada) a 91,44 m (100
yardas). Por lo tanto, si el punto de impacto está a 5,08 cm (dos pulgadas)
por debajo y a 2,54 cm (una pulgada) a la derecha en el ajuste de paralaje de
91,44 m (100 yardas), deberá ajustar dos minutos de ángulo hacia arriba y
un minuto de ángulo hacia la izquierda. En caso de que el ajuste de paralaje
sea de 45,72 m (50 yardas), el valor del ajuste será el doble. En el caso de
que el ajuste de paralaje sea de 68,58 m (75 yardas), será de 1,5 veces.
Mantenimiento
(1) Limpieza del objetivo
(1) Para quitar la suciedad de las huellas dactilares, remoje una gasa para
limpieza de lentes, papel (papel sin silicio disponible en tiendas de venta
de cámaras) con alcohol puro (en farmacias) y frote ligeramente. No se
recomienda utilizar pañuelos de cuero ya que podría dañar la superficie de
la lente.
(1) El polvo puede rayar la superficie de la lente o desgastarla.
(1) Quite el polvo con un cepillo suave sin aceite.
(2) Exterior de la mira
(1) Utilice un paño suave para eliminar cualquier suciedad o las huellas dacti-
lares que se hayan acumulado.
(1) No es necesario aceitar la superficie de la mira.
(3) Dispositivos de ajuste del efecto del viento/elevación
(1) Estos dispositivos de ajuste están permanentemente lubricados. No intente
lubricarlos. Cúbralos con las tapas suministradas excepto cuando los
ajuste, para evitar el polvo y la suciedad.
(4) Dispositivo de ajuste del ocular
(1) Este dispositivo de ajuste está permanentemente lubricado. No intente
lubricarlo.
(5) Anillo selector de potencia
(1) El anillo selector de potencia no debe lubricarse.
(1) No afloje ni quite los tornillos del anillo selector de potencia.
3. Istruzioni
(1) Messa a fuoco
(1) Guardando attraverso l’oculare mentre se ne mantiene l’occhio a circa 10
cm di distanza (fig. 3-1), si potrà vedere il reticolo Nikoplex (fig. 3-2), il
reticolo BDC (fig. 3-3), il reticolo Milliradian Dot (fig. 3-4), il reticolo
filare (fig. 3-5) oppure il reticolo filare con punto (fig. 3-6).
(1) Assicurarsi di tenere l'occhio allineato correttamente con un sollievo
occhio appropriato altrimenti la visione diventa "nera".
(1) Puntare l'obiettivo del mirino verso il cielo (mai verso il sole) o verso
una parete liscia di colore uniforme.
(1) Allentare l'anello di blocco. (solo 2x20)
(1) Ruotate il dispositivo di regolazione dell'oculare in senso antiorario e
quindi in senso orario sino a quando il reticolo appare ben nitido.
(1) Usare il punto 0(zero) di diottria e l’indice della potenza oculare riferito
alla potenza del vostro occhio. (fig.3-7)
(2) Ingrandimento
(1) II Nikon Riflescope 3-12x42 SF ha un ingrandiment variabile da 3 a 12x
quello 2.5-10x42 si 2.5-10x50 quello 2.5 a 10x, quello 4-16x42 SF da 4
a 16x quello 5-20x44 SF quello 6-24x50 SF da 6 a 24x.
(1) Per cambiare l'ingrandimento, basta girare l'anello di selezione ingrandi-
mento fino a che l'ingrandimento desiderato appare a fianco del punto di
indice ingrandimento.
(3) Regolatore del mirino
(1) Guardando attraverso il mirino, allineare il fucile con il punto di mira sul
bersaglio e sparare un colpo di prova. Se il proiettile non colpisce il punto
mirato, regolare l'elevazione e la compensazione vento come segue:
(1) Se il proiettile colpisce sotto il punto di mira, girare il regolatore dell'el-
evazione (in senso antiorario) in direzione della freccia con la scritta "U"
(up=su in inglese) come nella Fig. 3-8. Se il proiettile colpisce piu in
alto, girare il regolatore (in senso orario) in direzione della freccia con la
scritta "D" (down=giù in inglese).
(1) Se il proiettile colpisce a destra del punto di mira, girare il regolatore per
il vento (in senso orario) in direzione della freccia con la scritta "L"
(left=sinistra in inglese) come nella Fig. 3-9. Se il proiettile colpisce a
sinistra del punto di mira, girare il regolatore (in senso antiorario) in
direzione della freccia con la scritta "R" (right=destra in inglese).
(1) Per il regolazione della manopola di Profilo Alto viene eseguita girando
manualmente il manopola. Se il proiettile colpisce sotto il punto di mira,
girare il manopola in direzione della freccia con la scritta "U" (Fig.3-10).
Se il proiettile colpisce a sinistra del punto di mira, girare la manopola
in direzione della freccia con la scritta "R" (Fig. 3-11).
(4) Obiettivo regolabile
(3) I Nikon Riflescope, 3-12x42 SF, 4-16x42 SF, 5-20x44 SF, 6-24x50 SF
possono essere messi a fuoco con maggiore precisione nella gamma da
almeno 50 iarde (45,72 m) all'infinito girando l'anello di regolazione dell'o-
biettivo.
(3) Il parallasse può essere eliminato e l'allineamento della mira sarà accurato.
(3) L’anello di regolazione ha un sistema di blocco, in modo che esso non si
muova durante lo sparo. Quando si regola la messa in fuoco, tirare fuori
l’anello di regolazione. Per il blocco, premere dentro l’anello di regolazione.
(fig. 3-12)
(5) Sostituzione della manopola (5-20x44 SF e 6-24x50 SF sono for-
niti, un altro mirino è opzionale. )(
(3) Rimuovere il cappuccio protettivo della manopola girandolo in senso antio-
rario. Allineare manopola con la posizione 0 (zero) dell'anello di scala.
Questo serve ad assicurare che l'anello di scala sia allineato correttamente
con la nuova manopola (la posizione di allineamento deve essere ricorda-
ta).
(3) Trattenendo manopola con le dita per evitare che l'anello di scala si sposti,
girare il vite in cima al manopola in senso antiorario con ila chiave esago-
nale in dotazione fino a che il vite fuoriesce. Quindi rimuovere manopola
(Fig. 3-13).
(3) Inserire la nuova impugnatura in posizione e allineare l'anello di scala con
0.
(3) Inserire il vite. Trattenendo manopola con le dita per evitare che l'anello di
scala si sposti, girare il vite in senso orario con la moneta, fino a che
manopola è fissata saldamente.
(6) Azzeramento della manopola (fig. 3-14)
(3) Dopo che il reticolo è stato regolato per il punto di impatto, trattenendo
manopola con le dita per evitare lo spostamento della manopola allineata,
girare la vite della manopola in cima all'impugnatura con una moneta in
senso antiorario. Poi sollevare manopola e allineare " " con il segno di
indice. Può succedere che " " non si allinei esattamente con il segno di
indice a causa della giustezza di accoppiamento dell'impugnatura con la
canna. Trattenendo l'impugnatura con le dita per evitare spostamenti della
manopola, girare la vite della manopola in senso orario con una moneta
fino a che manopola è fissata saldamente.
Nota:
Le scale di compensazione vento e Nikon Riflescope 3-12x42 SF, 2.5-
10x42, 2.5-10x50 e 4-16x42 SF sono calibrate in divisioni di 1/4 di minuto
di angolo con scatti a intervalli di 1/4 di minuto di angolo (una divisione).
Le scale di compensazione vento e Nikon Riflescope 5-20x44 SF e 6-24x50
SF sono calibrate in divisioni di 1/8 di minuto di angolo con scatti a inter-
valli di 1/8 di minuto di angolo (una divisione).
Quando dovete regolare il reticolo sul punto di mira, ricordate che un minuto
d'angolo corrisponde a circa 2,54 cm (1 pollice) alla distanza di circa 91,44
m (100 iarde). Di conseguenza, se il punto di impatto si trova circa 5,08 cm
(2 pollici) sotto e 2,54 cm (1 pollice) a destra alla distanza di 91,44 m (100
iarde), la regolazione di parallasse deve consistere in due muniti d'angolo in
alto ed un minuto d'angolo a sinistra. Con gli stessi scostamenti ma alla dis-
tanza di 45,72 m (50 iarde), la regolazione di parallasse sarà doppia, mentre
a circa 68,58 metri (75 iarde) sarà di 1,5.
Manutenzione
(1) Pulizia delle lenti
(1) Per rimuovere sporco o impronte digitali, inumidire garza o carta di pulizia
per obiettivi (carta senza silicio in vendita nei negozi di articoli fotografici)
con una piccola quantità di alcool assoluto (reperibile in farmacia) e pas-
sare con delicatezza. Non si consiglia di usare fazzoletti o pelle perchè pos-
sono danneggiare la superficie della lente.
(1) La polvere può graffiare la superficie della lente o corrodere la lente.
Togliere la polvere usando uno spazzolino morbido non oleoso.
(2) Esterno del mirino
(1) Usare un panno morbido asciutto per eliminare sporco e impronte digitali
accumulati.
(1) Non è necessario oliare la superficie del mirino.
(3) Regolatore per il vento/elevazione
(1) Questi regolatori sono lubrificati permanentemente. Non tentare di lubrifi-
carli. Coprire con i cappucci in dotazione, tranne durante la regolazione,
per evitare la penetrazione di polvere e sporco.
(4) Regolatore dell'oculare
(1) Questo regolatore è lubrificato permanentemente. Non tentare di lubrificar-
lo.
(5) Anello di selezione ingrandimento
(1) Non è necessaria alcuna lubrificazione dell'anello di selezione ingrandi-
mento. Non allentare o rimuovere viti dell'anello di selezione ingrandimen-
to.
O (Zero) diopter
O (Null) stäken punkt
O (Zéro) Paint de diopter
O (Zero) punto de diottrica
O (Zero) punto di diottre
Exepiece power index
Okularstä kenindec
Oculaire díndec de puissance
Punto de índice de potencia
Punto indice di delloculare
Eyepiece Adjustment
Okulareinstellung
Réglage d'oculaire
Dispositivo de ajuste del ocular
Regolatore oculare
Eye Relief
Abstand der Austrittspupille
Dégagement oculaire
Distancia aprox. de la pupila de salida al ocular
Sollievo occhio
The reticle should be immediately crisp and clear to the quick glance.
Das Fadenkreuz soll sofort auf den ersten Blick scharf unddeutlich wirken.
Le réticule doit apparaître clair et net au premier coup d'œil.
El retículo debe ser inmediatamente preciso y claro para el vistazo rápido.
Il reticolo deve apparire immediatamente nitido e chiaro ad un'occhiata rapida.
Nikoplex Reticle
Nikoplex Fadenkreuz
Réticule Nikoplex
Retículo Nikoplex
Reticolo Nikoplex
Fig. 3-1
Abb. 3-1
Fig. 3-7
Abb. 3-7
Fig. 3-2
Abb. 3-2
Fig. 3-12
Abb. 3-12
Fig. 3-5
Abb. 3-5
Fig. 3-4
Abb. 3-4
Miliradian Dot Reticle (2.5-10x44, 4-16x42 SF only)
Milliradianpunkt-Fadenkreuz (nur 2.5-10x44, 4-16x42 SF)
Réticule à points miliradian (2.5-10x44, 4-16x42 SF seulement)
Retículo de punto milirradián (2.5-10x44, 4-16x42 SF solamente)
Reticolo a punti milliradiante (solo 2.5-10x44, 4-16x42 SF)
Crosshair Reticle (6-24x50 SF only)
Dünnes Fadenkreuz (nur 6-24x50 SF)
Réticule à croisée de fils (6-24x50 SF seulement)
Retículo en cruz (6-24x50 SF solamente)
Reticolo a croce (solo 6-24x50 SF)
FREE
FREI
LIBRE
LIBRE
LIBERO
LOCK
SCHLOB
SERRURE
CERRADURA
SERRTUNA
Crosshair with dot Reticle (6-24x50 SF only)
Fadenkreuz mit Punkt (nur 6-24x50 SF)
Réticule à croisée de fils avec point (6-24x50 SF seulement)
Retículo en cruz con punto (6-24x50 SF solamente)
Reticolo filare con punto (solo modello 6-24x50 SF)
BDC reticle
BDC Fadenkreuz
Réticule BDC
Retículo BDC
Reticolo BDC
Fig. 3-3
Abb. 3-3
Fig. 3-6
Abb. 3-6
1/4''
1/8''
Fig. 3-10 (1/8'')
Abb. 3-10 (1/8'')
Fig. 3-13
Abb. 3-13
Fig. 3-14
Abb. 3-14
Fig. 3-14
Abb. 3-14
Fig. 3-11 (1/8'')
Abb. 3-11 (1/8'')
Fig. 3-9
Abb. 3-9
Fig. 3-8
Abb. 3-8
Fig. 3-14
Abb. 3-14
1/4''
1/8''
1 / 1

Nikon MONARCH III Manuale utente

Categoria
Binocolo
Tipo
Manuale utente
Questo manuale è adatto anche per