1 Notes on the documentation
5
1.1 Application 5
1.2 Layout of the documentation 5
1.3 Representation convention 5
2 Safety instructions and regulations
6
2.1 Safety instructions and warning notices 6
2.2 Basic safety instructions 7
2.3 Property damage 9
3 Product description
9
3.1 General view and elements 9
3.2 Intended purpose 10
3.3 Designation 11
3.4 Technical specifications 11
3.5 Operating temperatures 11
4 Controls
11
4.1 Main switch and button 11
4.2 Control panel 12
4.3 Operating states 13
4.4 Displays faults and information 14
4.5 Overview of display symbols 14
4.6 Overview of information display 16
5 Installation
17
5.1 Personnel qualification 17
5.2 Special safety instructions 17
5.3 Transporting to the installation location 18
5.4 Removing the packaging 18
5.5 Installing the machine 18
5.6 Assembly of modules 19
5.7 Attach electrical consumers 20
5.8 Tension conveyor belt 20
5.9 Connecting to the power supply 22
5.10 Connecting the water 22
5.11 Connecting the drain 23
5.12 Connect steam or hot water 23
5.13 Connecting the exhaust 24
5.14 Connect detergent and rinse aid 26
6 Commissioning
27
6.1 Personnel qualification 27
6.2 Special safety instructions 27
PREMAX FTPi series (Protronic XL)
Installation and Operation Instructions
2 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
6.3 Preparing the machine 28
6.4 Fill the booster 28
6.5 Carry out checks 31
6.6 Making the chemical settings 32
6.7 Setting the autotimer (option) 32
6.8 Setting the automatic commissioning 32
6.9 Adjusting the exhaust system 32
7 Operation
32
7.1 Personnel qualification 32
7.2 Special safety instructions 33
7.3 Notes for optimum washing result 33
7.4 Preparations for washing 34
7.5 Functions and operating modes 40
7.6 Pressing the EMERGENCY STOP button 41
7.7 Washing 42
7.8 Selecting the conveyor speed 43
7.9 Manually activating and deactivating high-pressure washing 43
7.10 Activating conveyor return 44
7.11 Locking the conveyor speed 44
7.12 Activating emergency mode 45
7.13 Displaying faults 45
7.14 Switch off conveyor 46
7.15 Switch off machine 47
7.16 Executing daily cleaning 47
7.17 Performing monthly cleaning 56
7.18 Entering messages 57
7.19 Displaying machine documentation 58
8 Setting options, operating and hygiene data
59
8.1 Overview of operator menu 59
8.2 Opening the operator menu 60
8.3 Displaying the operating/hygiene data 61
8.4 Setting the automatic commissioning 62
8.5 Entering the time settings 62
8.6 Displaying information 63
8.7 Setting customer options 64
9 Fault indications and problems
66
9.1 Special safety instructions 66
9.2 Fault indications 66
9.3 Remedying the problem 70
10 Maintenance
72
11 Disposal
76
Installation and Operation Instructions
PREMAX FTPi series (Protronic XL)
HOBART 0000000218-001-EN / 10. Jul. 2019 3
EN
12 Product disclaimer
76
13 Conformity
77
PREMAX FTPi series (Protronic XL)
Installation and Operation Instructions
4 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
1 Notes on the documentation
1.1 Application
This document contains the most important information for the installation and commissioning of the machine by
qualified personnel, as well as the information required for day-to-day operation by the operator.
Keep the operation manual and all referenced documents in a safe and accessible place.
Store the operation manual in a suitable container protected from humidity and dirt deposits.
If you sell the machine, pass on the installation and operation manual.
1.2 Layout of the documentation
Referenced documents are all instructions that describe the installation, operation, maintenance and repair of the
device, as well as additional instructions for all accessories used.
For the operator:
Comic Card (brief instructions)
Operation instructions
For the specialised tradesman or HOBART service:
Installation instructions
Floor plan
Circuit diagram
Service Manual
Service Software Manual
Trouble shooting list
Maintenance schedule
Spare Parts Catalogue
1.3 Representation convention
1.3.1 Symbols used
Symbol Meaning
Warning of hazardous electrical voltage
EX
Beware of explosion
Warning of risk of crushing
Beware of entanglement
Beware of hazardous substances
Beware of hand injuries
PREMAX FTPi series (Protronic XL)
Notes on the documentation
HOBART 0000000218-001-EN / 10. Jul. 2019 5
EN
Installation and Operation Instructions
Symbol Meaning
Beware of slipping
Beware of hazard area
Useful additional information and tips
1.3.2 Representation in the text
Representation Meaning
NOTE Important information on machine operation, not a warning notice
Step
Outcome/result
Listing 1st level
Listing 2nd level
2 Safety instructions and regulations
2.1 Safety instructions and warning notices
During machine operation, observe the general safety instructions and warning notices that precede each
action.
2.1.1 Hazard levels
The hazard level is part of the safety instructions and is denoted by the signal word.
Potential consequences are differentiated by the choice of signal word.
DANGER
imminent danger:
results in serious physical injury or death
WARNING
potentially hazardous situation:
can cause serious physical injury or death
CAUTION
potentially hazardous situation:
can cause minor physical injury
NOTICE
potentially harmful situation:
can cause damage to the product or other objects
2.1.2 Layout of warning notices
Warning notices are depicted with warning symbols and signal word in the corresponding safety colours.
PREMAX FTPi series (Protronic XL)
Safety instructions and regulations
6 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
CAUTION!
Nature and source of the hazard
Explanation on the nature and source of the hazard
Measures for averting the hazard
additional measures for averting the hazard, where applicable
2.2 Basic safety instructions
2.2.1 Product safety
The machine conforms to state-of-the-art technology and the recognised safety regulations. Nonetheless, hazards
may occur.
Operate the machine only in compliance with the operation manual.
All modifications and alterations to the product are reserved for persons authorised by HOBART.
2.2.2 Personnel qualification
Observe the regulations on occupational health and safety. Wear personal protective equipment.
Carefully read through the Installation and Operation Manual before use.
Activity User group Qualification/training
Installation Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
Trainees Only under professional supervision and examination
Commissioning Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
Trainees Only under professional supervision and examination
Work on electrical sys-
tem
Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
Work on refrigeration
systems
Qualified personnel Category 1 expert certified in accordance with:
- Ordinance (EU) No. 517/2014 Article 10
- Implementing regulation (EU) 2015/2067
- German Chemicals Climate Protection Ordinance §5
Operation Operating personnel
and persons over the
age of 14
Only under supervision and after instruction by the operator on
the basis of the operating instructions, instructions on dangers
Disabled persons The suitability must be assessed by the operator on an individ-
ual basis
Persons up to the age
of 13
Persons up to the age of 13 are not suited for machine opera-
tion
Maintenance, repair Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
PREMAX FTPi series (Protronic XL)
Safety instructions and regulations
HOBART 0000000218-001-EN / 10. Jul. 2019 7
EN
Installation and Operation Instructions
Activity User group Qualification/training
Trainees Only under professional supervision and examination
2.2.3 Product-specific hazards
Avoid body parts being crushed or knocked:
Observe the instructions on the packaging for storage, lifting or transporting.
Transport is reserved for certified and trained personnel.
Only certified qualified personnel are permitted to install the machine, assemble the modules, tension the con-
veyor belt and connect the exhaust pipework.
Ensure that the operators wear tight-fitting clothing.
Do not reach into the conveyor system during operation.
Carefully remove the wash arms when cleaning the machine.
Risk of body parts being cut:
Wear personal protective equipment when removing the packing bands, unpacking the modules and tensioning
the conveyor belt.
Only certified, qualified personnel are permitted to connect the exhaust pipework and set the exhaust system.
Wear protective gloves when cleaning the machine.
Only certified personnel are permitted to clean the exhaust condenser.
Avoid risk of explosion:
Do not install machine in a potentially-explosive location.
Avoid electric shock:
Do not allow water to flow over live components.
Make sure the machine is correctly stored (see frost damage section 2.3).
Do not spray the outside of the machine with a water hose or high-pressure cleaner.
Have the machine connected to the power supply by qualified personnel.
Have the booster and the fill booster initially filled and the motors checked only by certified, qualified personnel
and in accordance with the operation instructions.
Have wearing or faulty parts replaced only by certified, qualified personnel.
Avoid fire risk:
Do not allow water to flow over live components.
Make sure the machine is correctly stored (see frost damage section 2.3).
Do not spray the outside of the machine with a water hose or high-pressure cleaner.
Have the machine connected to the power supply only by qualified personnel.
Have all modifications to the machine, repairs and maintenance carried out only by qualified personnel.
Avoid chemical burns, sensitisation of the skin, poisoning:
Wear protective equipment (gloves, safety goggles, protective clothing) when handling chemicals.
Use only suitable chemicals. Observe the manufacturer's data.
Do not open the door during operation.
Disconnect the machine from the mains prior to cleaning.
Avoid burns, scalds (to the hands):
Wear protective gloves when connecting to the site steam pipework.
Do not open the door during operation.
Disconnect the machine from the mains prior to cleaning.
For cleaning, wear protective equipment (gloves, protective clothing) when touching parts that have hot surfaces
(heating rods, heat exchangers).
PREMAX FTPi series (Protronic XL)
Safety instructions and regulations
8 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
Avoid risk of falling:
Do not stand on the machine roof when connecting the exhaust pipework.
Avoid slipping:
Moisture can build up on the machine floor.
Provide a floor covering that is guaranteed to be non-slip in case of moisture.
Residues on the washware, hygiene regulations not maintained.
Hygiene regulations must be maintained and/or demonstrated in accordance with the national provisions.
2.2.4 Additional hazards
Potential hazards caused by operating resources to be used can be found in the enclosed safety datasheets. Work-
places must be signed accordingly.
2.3 Property damage
Avoid frost damage:
Temperatures below 0°C lead to functional damage.
Before storing below 0°C, empty residual water in hoses, tank and boiler.
Prior to restart, store the machine at room temperature (min. 15°C) for 24h.
Avoid water damage:
Do not operate the machine without supervision.
Close on-site shut-off valves at the end of operation.
3 Product description
3.1 General view and elements
Example: Model SADL
3.1.1 Curtain arrangement
Illustration applies to left/right running direction. The curtain arrangement is reversed for right/left running direction.
PREMAX FTPi series (Protronic XL)
Product description
HOBART 0000000218-001-EN / 10. Jul. 2019 9
EN
Installation and Operation Instructions
S-DA
E-S-A
S-A
L-A
L AN-R
S AN-R
3.2 Intended purpose
The machine is an item of technical equipment intended solely for commercial dishwashing.
The machine is designed solely for cleaning crockery (porcelain, glass, ceramic, temperature-resistant plastics or
stainless steel or similar) from the food industry.
Not for washing:
PREMAX FTPi series (Protronic XL)
Product description
10 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
Containers that do not come into contact with foodstuffs, such as ashtrays, candlesticks, electric appliances etc.
Animals or textiles
Foodstuffs intended for further consumption
3.3 Designation
The rating plate is located on the control box and contains the following information: model, serial number, date of
manufacture, country of manufacture, voltage, connection rating, design-state number and CE mark.
3.4 Technical specifications
See separate floor plan.
Noise emission:
Workplace-related emission value:
Emission sound pressure level LpA = 73.6 dB (A)
Measurement uncertainty KpA = 2.5 dB
3.5 Operating temperatures
Prewash tank 45-55°C
Main wash tank 63-67°C
Pumped rinse 70-80°C
Fresh water rinse 62-65°C
4 Controls
4.1 Main switch and button
EMERGENCY STOP button
Machine is completely switched off, but not voltage free.
Must be unlocked for operation.
Main switch
For operation, must be set to position I, for repair and maintenance work to position 0.
CONVEYOR ON button at the entry section (option)
Switches on the machine conveyor.
Washing is started automatically.
CONVEYOR OFF button at the entry section (option)
Switches off the conveyor and wash functions.
HIGH-PRESSURE button at the loading section (option)
Turns on the high-pressure program (illuminates during high-pressure mode).
Press the button again to turn off.
PREMAX FTPi series (Protronic XL)
Controls
HOBART 0000000218-001-EN / 10. Jul. 2019 11
EN
Installation and Operation Instructions
4.2 Control panel
4.2.1 Start screen
The Protronic XL operating and display unit is a 7" colour touch display. All functions are selected via this operating
interface. The illustrations (temperatures, symbols) are examples and may vary depending on model and features
installed. It may take the controller some time to boot up. This is normal and does not indicate a fault.
Title Function
MACHINE ON button Pressing this button switches the machine on.
OPERATOR MENU button Pressing this button selects the operator menu (see section
4.5.2).
Display Date and time
Display Machine designation and serial number
4.2.2 Main screen
Below the machine display, selected programs and operating states are explained by symbols and texts. If faults
are present, symbols and the display frame change colour.
Title Function
Symbol display Displays the current setting and information on the operating state
of the machine through function symbols (see section 4.5.1).
Information display Displays the current operating state as text.
PREMAX FTPi series (Protronic XL)
Controls
12 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
Title Function
MACHINE OFF button Pressing this button switches the machine off.
Press for 5 seconds:
Machine will be completely drained and
then switched off.
CONVEYOR OFF button Pressing this button switches the conveyor off.
CONVEYOR ON button Pressing this button switches the conveyor on. Washing, rinsing
and drying start.
The button also shows the current operating state through differ-
ent colours (see sections 4.3 and 4.4 )
SPEED 1 button Pressing this button selects conveyor speed 1.
SPEED 2 button Pressing this button selects conveyor speed 2.
SPEED 3 button Pressing this button selects conveyor speed 3.
OPERATOR MENU button Pressing this button selects the operator menu (see section
4.5.2).
4.2.3 Operator menu screen
In the operator menu, machine functions are selected and operating data, faults and information messages are dis-
played.
Title Function
Help Displays help on the menu
Forwards/backwards Scroll in the menu
Quick menu Select machine functions
Operating data Enter and display operating data
AutoStart Enter AutoStart and time settings
Fault Display fault and information messages
User menu Open the user menu, login required
Service Only for authorised service personnel, login required
Home Back to the main screen
4.3 Operating states
In the operating panel display, the function keys show the current operating state through different colours.
PREMAX FTPi series (Protronic XL)
Controls
HOBART 0000000218-001-EN / 10. Jul. 2019 13
EN
Installation and Operation Instructions
Example: SPEED 1 button
Colour Meaning
Grey faded out Not available
Grey faded in Inactive
Blue Active
Yellow Minor error
Red Major error
4.4 Displays faults and information
Faults are shown in the operator panel display. Information can be displayed in the operator menu.
Fault: Major error
Display field frames and symbols are red.
The warning symbol appears in the symbol display: Exclamation mark is red.
The text: Fault! appears in the information display
For potential faults, see section 9.2
Fault: Minor error
Display field frames and symbols are yellow.
The warning symbol appears in the symbol display: Exclamation mark is yellow.
The text: Fault! appears in the information display
9.2For potential messages, see section
Information
Information messages are displayed only in the operator menu.
Warning symbol: Exclamation mark is blue.
9.2For potential messages, see section
4.5 Overview of display symbols
4.5.1 Function symbols
The symbol display shows the current setting and information on the operating cycle of the machine.
Symbol Function
All tanks: Drain water
PREMAX FTPi series (Protronic XL)
Controls
14 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
Symbol Function
Machine fills
Doors/covering opened
AutoStart enabled
Fault: minor error, major error, information
Pan program: Manual
Hygiene control enabled
AUTOCLEAN running
Emergency mode enabled
New message available
4.5.2 Menu symbols
In the operator menu, machine functions are selected and operating data, faults and information messages are dis-
played.
Icon Function
Displays help on the menu
Scroll forwards and backwards in the menu
PREMAX FTPi series (Protronic XL)
Controls
HOBART 0000000218-001-EN / 10. Jul. 2019 15
EN
Installation and Operation Instructions
Icon Function
Quick menu: Select machine functions
Enter and display operating data
Enter AutoStart and time settings
Fault
Open the user menu, login required
Service: Only for authorised service personnel
Home: Back to the main screen
Delete message
Write message
Confirm setting
4.6 Overview of information display
The current operating mode is displayed in the information line. Information includes:
Text Meaning
Machine filling, please wait! Fill operation before operational readiness.
Machine heating, please wait! Heating operation before operational readiness.
Machine is ready for operation Machine is filled, operating temperatures are reached and there
are no faults or errors.
Conveyor is running Machine is operational and conveyor is switched on.
Depending on the operating mode (autotimer), the washing cycle
runs automatically once the washware has entered the machine
or at the same time as conveyor ON.
Washing switched on Depending on the operating mode (autotimer), the washing cycle
runs automatically once the washware has entered the machine
or at the same time as conveyor ON. When autotimer is active,
the washing cycle is switched on via the sensor at the machine
entry section
Transport and washing are switched on.
Door or covering opened One or more doors are opened.
PREMAX FTPi series (Protronic XL)
Controls
16 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
Text Meaning
Conveyor limit switch actuated Located at the exit end of the machine is a limit switch which is
pressed if the washware is not removed. This limit switch deacti-
vates the conveyor. The drive starts to run again automatically as
soon as the washware is removed.
Fault! One or more faults has occurred. Tapping the text message
opens the fault message menu.
Strainer in …….. missing The display indicates if a strainer is missing or incorrectly posi-
tioned in the tanks.
Machine in emergency mode If the temperatures for operational readiness are not reached, the
conveyor cannot be started. The customer can activate emer-
gency mode to rinse without operation readiness being reached.
Emergency mode is deactivated by switching off the machine.
Service due in ... hours The display shows the time remaining until the next due service
interval.
Service due The service interval hours have elapsed, service is due.
Prewash is being refilled The prewash(es) is/are drained and then refilled.
Machine is being drained The machine is completely drained (if necessary, this message
can also be displayed at the end of AUTOCLEAN).
AUTOCLEAN running The AUTOCLEAN program is active.
Switch off machine, please! The machine has been drained and can be switched off.
AUTOCLEAN is complete and the machine can be switched off.
5 Installation
5.1 Personnel qualification
Installation must only be carried out by qualified personnel (see section 2.2.2).
5.2 Special safety instructions
WARNING!
Risk of electric shock, fire hazard
Water (frost damage, machine overflow) flowing over live components can cause injury from elec-
tric shock or fire.
Do not allow water to flow under live components.
Make sure the machine is correctly stored (see frost damage section 2.3).
Make sure that the machine does not overflow when being filled.
WARNING!
EX
Risk of explosion
Installing the machine in a potentially explosive location can cause explosion and serious injury
from ejected parts.
Do not install machine in a potentially-explosive location.
PREMAX FTPi series (Protronic XL)
Installation
HOBART 0000000218-001-EN / 10. Jul. 2019 17
EN
Installation and Operation Instructions
NOTICE!
Frost damage
Temperatures below 0°C during transport/storage cause function impairments.
Prior to installation, store the machine at room temperature (min. 15°C) for 24h.
5.3 Transporting to the installation location
WARNING!
Risk of being crushed or knocked
When being lifted and transported, the machine can overturn or fall and cause serious injury.
Observe the instructions on the packaging for storage, lifting or transporting.
Have the machine transported only by certified and trained personnel.
If possible in its packing and on the skid.
If a forklift is used, put a wooden frame under the machine.
Use suitable transport means (elevating truck, crane etc.).
Push on rollers.
Avoid damage to floors and doors.
Avoid damage to the machine.
5.4 Removing the packaging
CAUTION!
Risk of being cut
Removing the packing bands can cause cut injuries. When unpacking the modules, the sharp
edges of the sheet parts can cause cut injuries.
Wear personal protective equipment.
Cut off packing bands.
Remove outside carton.
Remove skid.
Remove packing materials and accessories from the machine.
Inspect the machine for possible transport damage.
5.5 Installing the machine
CAUTION!
Risk of being crushed
Body parts can be crushed while the machine is being set down.
Have the machine installed only by certified, qualified personnel.
Wear protective gloves.
NOTE: If the machine is delivered in separate modules, align the largest machine part at the installation
location first (see also5.6).
PREMAX FTPi series (Protronic XL)
Installation
18 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
Align the machine according to the installation plan.
Observe wall clearances according to the installation plan.
By turning the feet, set the height of the loading platform to 920 mm.
Level out an unevenness in the floor.
Distribute machine weight equally onto all feet.
5.6 Assembly of modules
WARNING!
Risk of being crushed or knocked
When assembling modules, raised machine parts can overturn or fall and cause serious injuries.
Have the modules assembled only by certified, qualified personnel.
Wear personal protective equipment.
CAUTION!
Risk of being cut
When assembling modules, sharp edges on sheet parts can cause cut injuries.
Have the modules assembled only by certified, qualified personnel.
Wear protective gloves.
Remove covers.
Affixing sealing tape:
Remove any old seals.
Affix sealing strip no. 168 834-14 all the way around one of the
two contact surfaces.
Allow the strip ends to overlap in the corners.
Adding next modules:
Level the height (see 5.5).
Connect modules (use screws SK M6 x 12, washers, spring
rings and nuts supplied).
Cut off protruding sealing tape with knife.
Connect the drain pipes.
Connecting wash tanks:
Install overflows. :
PREMAX FTPi series (Protronic XL)
Installation
HOBART 0000000218-001-EN / 10. Jul. 2019 19
EN
Installation and Operation Instructions
Set sealing ring (A) on the overflow pipe (B).
B
A
C
E
D
Put the overflow pipe (B) from the inside of the tank through the pre-punched hole and tighten it with the nut
(C).
Push coupling (E) over pipe (D). Attach the pipe to the overflow (B) and connect with the overflow pipe of the
opposite wash tank.
Remove transport feet (if present):
Unscrew transport feet and return to the HOBART branch.
5.7 Attach electrical consumers
NOTE: Follow the wiring diagram and the labels on wires and terminals.
Unroll cable bundles and draw through the front cable channel.
Screw the cables to the connection terminals of the consumers.
5.8 Tension conveyor belt
CAUTION!
Risk of being cut or crushed
Rotating parts can cause crushing or cut injuries as the conveyor belt is being tensioned.
Have the conveyor belt tensioned only by certified, qualified personnel.
Wear personal protective equipment.
The belt must be tensioned by hand. Use of the belt drive is not permitted.
PREMAX FTPi series (Protronic XL)
Installation
20 0000000218-001-EN / 10. Jul. 2019 HOBART
EN
Installation and Operation Instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

Hobart Protronic XL PREMAX FTPi Series Installation And Operation Instructions Manual

Categoria
Lavastoviglie
Tipo
Installation And Operation Instructions Manual

in altre lingue