Munters BI28SPM Manuale del proprietario

Tipo
Manuale del proprietario
1© Munters Corporation, May 2017
QM1112r3
Instruction Manual
BI28SPM Ceiling Inlet
Bi-Flow, Spring/Mechanical
Models: BI28SPM • BI28SPM-01
BI28SPM
Ceiling Inlet
© Munters Corporation , May 2017
2
QM1112r3
BI28SPM Inlet
Instructions for Use and Maintenance
Thank You:
Thank you for purchasing a Munters inlet. Munters equipment is designed to be the highest performing, highest
quality equipment you can buy. With the proper installation and maintenance it will provide many years of
service.
Please Note:
To achieve maximum performance and insure long life from your Munters product it is essential that it be installed
and maintained properly. Please read all instructions carefully before beginning installation.
Warranty:
For Warranty claims information see the “Warranty Claims and Return Policy” form QM1021 available from the
Munters Corporation office at 1-800-227-2376 or by e-mail at [email protected].
Conditions and Limitations:
• Products and Systems involved in a warranty claim under the “Warranty Claims and Return Policy” shall have
been properly installed, maintained and operated under competent supervision, according to the instructions
provided by Munters Corporation.
Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation
or maintenance shall not be considered a defect under the Warranty.
3© Munters Corporation, May 2017
QM1112r3
Index
Chapters Page
1. Unpacking the Equipment 4
1.1 Parts List 4
1.2 Inlet Dimensions 4
2. Installation Instructions 5
2.1 Framing 5
2.2 Inlet Mounting 6
3. Latch Operation 9
4. Cabling 10
5. Operation 12
6. Performance Data 13
7. Exploded View and Parts List 14
© Munters Corporation , May 2017
4
QM1112r3
1.1 Parts List
Unpacking the Equipment
1.
Before beginning installation, check the overall condition of the equipment. Remove packing materials, and examine all
components for signs of shipping damage. Any shipping damage is the customer's responsibility and should be reported
immediately to your freight carrier.
1.2 Inlet Dimensions
31
7
16
Each BI28SPM Inlet includes:
1 - Plastic Frame with 2 doors attached
1 - Insulation Stop, 12” tall
2 - Spring Counterweight Assembly
1 - Hardware Package as follows
4
3
16
27
9
16
6
1
16
3
1
4
3
1
4
HP1239 for BI28SP/BI28SPM Inlets
ID Qty. Cat. No. Description
[A] 8 KS1402 #9-15 x 1.5” Hex Head Screw
[B] 1 AC1381
1
8” Dia. Cable Clamp, ZP
5© Munters Corporation, May 2017
QM1112r3
2.1 FRAMING
Step 1
Construct a framed opening in ceiling that is
25
1
2”W. x 25
1
2”L. and fasten to trusses or
bracing between trusses. Trim out framing with
‘J’-trim if a metal ceiling is used. See Figure 1A
and 1B. If inlet is being installed in a house
with a Tri-Ply ceiling, construct frame as shown
in Figure 1C.
Installation Instructions
2.
Figure 1A
Figure 1B
Step 2A
The Spring Counterweight Assemblies
and other hardware will already be
assembled as shown in Figure 2. The
Lift Line should be turned towards
actuator and Eye Bolt will be away
from actuator.
Step 2B
The doors will be held closed with the
latch. Keep doors latched and remove
the (4) screws shown. While removing
these screws make sure the washer
comes off the inlet and stays with the
screw. These screws will be used in
Step 3.
See Figure 2.
Figure 1C
Figure 2
If installing inlets near heaters, it is
recommended to install the BI28/BI48 inlet
at a location far enough from heaters that
will give a maximum temperature of 150°F.
This should be approximately 2-3 ft. from
the heater.
IMPORTANT
!
© Munters Corporation , May 2017
6
QM1112r3
Installation InstructionsChapter 2
Step 3
Turn Spring Counterweight Assembly over and set on frame of inlet and secure assembly with (2) of
the screws and washers removed in Step 2B. See Figure 3. Repeat for other Spring Assembly.
2.2 Inlet Mounting
Figure 4
Step 4
Install provided Insulation Stop into framed opening as shown using screws or staples (not provided).
See Figure 4.
Figure 3
7© Munters Corporation, May 2017
QM1112r3
Installation InstructionsChapter 2
Figure 5A
Step 5
Apply bead of caulk around top of inlet as shown in Figure 5A. Position inlet into framed opening and
attach inlet using (8) Hex Head Screws [A] provided. See Figure 5B. Be careful not to over tighten as this
may pull the Inlet Frame out of shape.
Step 6
To ensure an airtight fit, caulk around outside of 2x4 Framing and Inlet Frame.
Figure 5B
© Munters Corporation , May 2017
8
QM1112r3
Installation InstructionsChapter 2
Step 7
Proceed to routing main actuator cable or rod through holes in Inlet Frame. It is required to utilize a spring
or weight on actuator cable end opposite actuator. Once the cable is routed and the actuator is in the open
position, begin connecting the Lift Lines from each inlet door to the actuator cable using Cable Clamp [B]
provided. See Figure 6A and 6B.
Figure 6A
Figure 6B
9© Munters Corporation, May 2017
QM1112r3
Latch Operation
3.
Step 8
Latch is pre-installed near center of door. Rotate latch upward to unlock and downward to lock.
When inlet is in normal operation, be sure latch is in up position so it does not interfere with door
closing. See Figure 7A and 7B.
Figure 7A
Latch Shown in Open Position
Figure 7B
Latch Shown in Closed Position
© Munters Corporation , May 2017
10
QM1112r3
Cabling
4.
Step 9
Attach pulleys in line with the main rod or cable running through each BI28/BI48. See Figure 8A and 8B.
Figure 8A
Figure 8B
11© Munters Corporation, May 2017
QM1112r3
CablingChapter 4
Step 10
On each end of the run of BI28/BI48 inlets run a cable
through pulleys to winch or actuator on one end and to
weights or return spring on other end.
See Figure 8A, 8B and 9.
Figure 9
Step 11
With the winch or actuator at its fully closed position, check and
readjust each BI28 door tightly closed. Use winch or actuator to
open and close inlets a few times to make sure the doors open and
close smoothly
© Munters Corporation , May 2017
12
QM1112r3
Operation
5.
Note:
To achieve a lower static pressure
move the spring toward hinges (inward)
and to achieve a higher static pressure
move spring towards outside of the inlet
(outward). See Figure 10.
Step 1
Start by setting each spring as light
as possible, that still allows the doors
to close when the fans are off. Note:
installation on a sloped ceiling will
typically require a heavier setting on the
high (uphill) side and a lighter setting on
the low (down hill) side.
Step 2
With inlets winched fully closed, turn
on your minimum ventilation fans.
Then adjust (release) the mechanical
hardware (actuator or winch) gradually
until you achieve the desired static
pressure. The winching limits the inlet
door opening so that all the doors open
evenly and the desired static pressure is
achieved when the minimum ventilation
fans run..
Step 3
Once the winching is set, turn fans off
and recheck to ensure all the inlets are
closing fully.
Figure 10
Note:
Spring Position settings
may vary from inlet to
inlet. Adjust each inlet
as needed.
13© Munters Corporation, May 2017
QM1112r3
Performance Data
6.
© Munters Corporation , May 2017
14
QM1112r3
Exploded View and Parts List
7.
15© Munters Corporation, May 2017
QM1112r3
This page left blank intentionally
© Munters Corporation , May 2017
16
QM1112r3
Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66.
Munters Corporation 2691 Ena Drive Lansing, MI 48917 U.S.A. Phone +1 800-227-2376, Fax +1 517-676-7078
www.munters.us
Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada/US Munters
Corporation Lansing, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S,
Phone +45 9862 3311,
India Munters India, Phone +91 20 3052 2520, Indonesia Munters, Phone +62 818 739 235, Italy Munters Italy S.p.A., Chiusavecchia,
Phone +39 0183 52 11, Japan Munters K.K., Phone +81 3 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone
+52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries
Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +34 91 640 09 02, Sweden Munters AB, Phone +46 8 626 63 00, Thailand
Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endüstri Sistemleri A.Ş, Phone +90 322 231 1338, USA Munters Corporation Lansing, MI Phone
+1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 3825 6838, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +39 0183 52 11
BI28 Inlets are developed and produced by Munters Corporation, Lansing, Michigan U.S.A. 1-800-227-2376
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Munters BI28SPM Manuale del proprietario

Tipo
Manuale del proprietario

in altre lingue