SEA Gate 1 DG R1 Manuale del proprietario

Categoria
Gate Opener
Tipo
Manuale del proprietario
tras
GATE 1 DG R1
With inverter module
Rev.03 - 08/2015
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
67411665
English
CONTROL UNIT FOR SLIDING GATES
(Cod. 23001235)
CN1 = Input/output connectors
CN2 = Courtesy light connector
CN3 = Power connector
CN4 = 24V~ connector
CN5 = Inverter control connector
Cn6 = Limit switch connectors
CNA = Receiver connector RX
CNP = Programming connector
CNS = RF FIX Receiver connector
EXP = Expansion module connector -
LSE card
JOLLY = Jolly and Jolly 2 connector
DS = Programming display
CMS = Inverter interface connector
OK = Programming button
DOWN = Programming button
UP = Programming button
R1 = Relay C motor command Courtesy light
F1 = 6.3AT fuse on 230V
F2 = Accessories 1A fuse
GATE 1 DG R1
INVERTER
CN2CN3
TR1
JOLLY
CN6
CN1
CMS
CN5
CN4
CNA
EXP
R1
UP DOWN OK
DS
CNP
F1
F2
COMPONENTS
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
CNS
CNS
RECEIVER RX
155 mm
85 mm
JOLLY-JOLLY2
TECHNICAL SPECIFICATIONS
Control unit power supply: 230 Vac Single-phase
Absorption in stand by: 30 mA
Environment temperature : -20°C +50°C
Specifications of external enclosure: 183 X 238 X 120 - IP55
SIGB
COM
SIGA
INTERFACE CARD
2
JUMPERS
WARNING: The control unit is designed with the automatic detection of not used N.C. inputs (Photocells, Stop and Limit
switch) except the SAFETY EDGE input. The exclude inputs in self-programming can be restored in the “Check inputs”
menu without need to repeat the programming (page 11).
The herein reported
functions are
available starting
from revision 22.
1
2
3 4
5 6
7 8
9
10
11
12
13
CN1
Start
Stop
Common
Antenna
START Pedestrian
Common
Photocell 1
Common
ANT COM START
PEDST
STOP COM PH1 PH2
EDGE
24VAUX
COM 24V(FL) (FL)-
Safety edge 1
Flash (-)
+ +
- -
AUX Programmable
(24V 500 mA max)
24V 500 mA max
(Accessories)
1
2
3 4
5 6
7 8
9
10
11
12
13
CN1
Photocell 2
Start
Stop
Common
Antenna
START Pedestrian
Common
Photocell 1
Common
ANT COM START
PEDST
STOP COM PH1 PH2
EDGE
24VAUX
COM 24V(FL) (FL)-
Safety edge 1
Flash (-)
+ +
- -
24V 500 mA max
(Accessories)
Photocell 2
Optional
Obligatory jumper
without accessory
connection.
24Vac
Max 150 mA
CN4
1
LIMIT SWITCH
CN6
CN7
Limit switch Opening 1 (Green)
Limit switch Closing 1 (Yellow)
24V (Red)
Common (White)
Limit switch Opening 1 (Green)
Limit switch Closing 1 (Yellow)
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
14
15
16 17
18 19
20
CN2
Nota: The connectors
CN6 and Cn7 are not
used if the Four limit
switch interface card is
connected.
CONNESSIONI
RADIO MODULE RF FIX
(CNS)
Connettore
ricevente
RF FIX
(Disponibile
dalla revisione
hardware R2)
Flash Light
Flash N
AUX Programmable
(24V 500 mA max)
3
QUICK START
PROGRAMMING
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
UPDOWN
ALL OTHER PARAMETERS HAVE DEFAULT SETTINGS WHICH ARE USEFUL FOR THE 90% OF
THE APPLICATIONS BUT CAN BE HOWEVER SET THROUGH THE SPECIAL MENU. FOR
ENTERING INTO THE SPECIAL MENU MOVE ON ONE OF THE MENU AND PRESS THE UP
AND DOWN BUTTONS AT THE SAME TIME FOR 5 S.
PROGRAMMING
BUTTONS
OK
DOWNUP
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
OK
1
2
3
OK
OK
UP
UP
OK
PRESS
BUTTON
STORED
TRANSMITTERS
START
MOTOR
MENU
SEA
SET
MENU
SEA
SET
OK
UP
LANGUAGE
ITALIANO
UP
Skip this step if you do not want to program a transmitter
Press the
button of the
TX to be
stored
OK to exit
Menu or press
the button of
the next TX to
be stored
Choose the type of
motor with
UP or DOWN
To confirm and return
to main menu
MENU
SEA
SET
RECEIVER
MISSING
If on the display
appears the item:
Check if a receiver has
been connceted
(see page 2)
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
6
7
8
9
OK OK
OK OK
OK OK
OK OK
OK OK
UP
UP
UP
UP
LOGIC
PAUSE TIME
START IN
PAUSE
PROGRAM-
MING
TEST START
10
With UP or DOWN
choose
the desired logic
To confirm and return
to main menu
With UP or DOWN
choose a delay for
automatic closing
To confirm and return
to main menu
Skip this step
if you want to work
in half-automatic
logic
With UP or DOWN
Choose ON
To confirm and return
to main menu
With UP or DOWN choose ON
to start times learning
At the end of the selflearning
the control unit returns automatically
to the main menu
With
UP or DOWN Choose
ON to start test
To confirm and return to
main menu
Skip this step if a TX has already been stored
(See
page 5)
(See
page 5)
UP
MENU
SEA
SET
OK
END
15
MENU
SEA
SET
OK
SPECIAL
MENU
16
UP
Press OK to return to the
display of the inputs state.
Press OK to enter the special menu.
MENU
SEA
SET
Choose ON with
UP or DOWN
if you want to reverse
the direction of
the motor rotation
Per confermare
e tornare
al Menu principale
5
OK OK
UP
REVERSE
MOTOR
The gate will execute a CLOSING-OPENING-CLOSING CYCLE
4
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
MENU
Default
SET
MENU FUNCTIONS TABLE GATE 1 DG R2BF
Description
Set value
Stop
Start
Start
Stop
Unloch
Storing of a command
for unlocking an
electric brake
Italian
English
French
Spanish
2 - TRANSMITTERS
External module
Pedestrian Start
Clear memory
Delete a transmitter
External module
Pedestrian Start
Delete single transmitter
Delete transmitter memory
Olandese
1 - LANGUAGE
Español
English
Français
Italiano
Dutch
Start
Pedestrian
Start
End
“Transmitters” menu output
Barrier
3 - MOTOR
Barrier
8 - START IN PAUSE
6 - LOGIC
Automatic
Open-stop-close-stop-open
2 buttons
Safety
Dead man
Open-stop-close-open
Automatic
Step by step type 1
Step by step type 2
Two buttons
Safety
Dead man
7 - PAUSE TIME
Setting from 1s to 4min.
OFF
(semi-automatic logics)
9 - PROGRAMMING
10 - TEST START
15 - END
Start command
Times learning start
In pause start is not acceped
In pause start is accepted
(See page 6)
(See page 6)
Automatic
1 240
Off
Off
On
Off On
Off On
Off
Off
Off
Off
Press OK to return to the display of the firmware version
and to the one of inputs state.
16 - SPECIAL MENU
Press OK to enter the special menu.
5 - REVERSE MOTOR
Off
On
Synchronized right motor
Synchronized left motor
Off
Lepus Fast
English
Lepus Fast
5
Barrier
FUNCTION LOGIC
AUTOMATIC LOGIC
A start impulse opens the gate. A second impluse during the opening will not be accepted.
A start impulse during closing reverses the movement.
SECURITY LOGIC
A start impulse opens the gate. A second impulse during opening reverses the movement.
A start impulse during closing reverses the movement.
STEP BY STEP TYPE 1 LOGIC
The start impulse follows the OPEN-STOP-CLOSE-STOP-OPEN logic.
STEP BY STEP TYPE 2 LOGIC
The start impulse follows the OPEN-STOP-CLOSE -OPEN logic.
DEAD MAN LOGIC
The gate opens as long as the START button of opening is pressed; releasing it the gate stops. The gate closes as
long as the button connected to the PEDESTRIAN START is pressed; releasing it the gate stops. To execute
complete opening and/or closing cycles the related pushbuttons must be constantly pressed.
2 PUSHBUTTONS LOGIC
One start opens, one pedestrian start closes. In opening the closing will not be accepted. In closing a start command
reopens, a pedestrian start command (closes) will be ignored.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-
automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 8-
START IN PAUSE and choosing ON or OFF. By default, the parameter is OFF.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-
automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 8-
START IN PAUSE and choosing ON or OFF. By default, the parameter is OFF.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-
automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 8-
START IN PAUSE and choosing ON or OFF. By default, the parameter is OFF.
NOTE 1: To have the automatic closing it is necessary to set a pause time, otherwise all the logic will be semi-
automatic.
NOTE2: It is possible to choose, whether to accept or not, the start in pause, selecting in the MENU the item 8-
START IN PAUSE and choosing ON or OFF. By default, the parameter is OFF.
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
The gate executes automatically the following cycle: CLOSING - OPENING - CLOSING.
Before starting the learning, make sure (through the test menu), that the relative limit switches of every
opening are employed.
WORKING TIMES SELF LEARNING
6
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
UPDOWN
SPECIAL MENU FUNCTIONS TABLE GATE 1 DG R1 INVERTER
For entering into the special menu move on one of the menu and press the UP and DOWN
buttons at the same time for 5 s. For exiting the special menu press END or move on one of the
menu and press the UP and DOWN buttons at the same time for 5 s.
SPECIAL MENU
10 100
17 - SPEED
Setting from 10 to 100
70
MENU SP
Default
SET
Description
Set Value
21 - OPENING SLOWDOWN
SPEED 1
22 - CLOSING SLOWDOWN
SPEED 1
20
20
10 60 from max. speed
Slowdown speed in opening
10 60 from max. speed
Slowdown speed in closing
33 - OPENING SENSITIVITY
MOTOR1
34 - CLOSING SENSITIVITY
MOTOR1
95
Disabled
Adjusts the intervention time
of the Encoder / Potentiometer
in opening
Off (Intervention excluded)
10% (Fast intervention)
99% (Slow intervention)
Disabled
Off (Intervention excluded)
10% (Fast intervention)
99% (Slow intervention)
Adjusts the intervention time
of the Encoder / Potentiometer
in closing
95
Enables the reading of
the potentiometer with
LE card.
Potentiometer
Reports the current position
of the potentiometer on the
leaf.
This parameter is useful for
seeing if the potentiometer
is read correctly.
Reports the impulses
stored by the control unit
when the leaf is fully open.
Reports the impulses stored
by the control unit when the
leaf of is fully close.
32 - ENCODER *
Off
- - - - - - - -
51 - I.PAR.M1 *
52 - I.AP.M1 *
53 - I.CH.M1 *
- - - - - - - -
- - - - - - - -
Off
32 - ENCODER *
In ON enables the Encoder,
in OFF it's disabled
Off
xxx.
Encoder impulses during operation
(Motor 1).
Encoder impulses stored in programming
(Motor 1).
xxx.
48 - ENCODER TOT.1 *
47 - ENCODER PAR.1 *
0.0A
57 - WORKING CURRENT
Shows motor absorption
during operation
Off 50
20
60 - CLOSING SLOWDOWN 1
From OFF to 50% of
the stroke. Note: Not active
if the Four limit switch
interface card is present
Off 50
20
59 - OPENING SLOWDOWN 1
From OFF to 50% of
the stroke. Note: Not active
if the Four limit switch
interface card is present
7
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
MENU SP
Default
SET
Description
Set Value
Off
Off
79 - ANTI INTRUSION
Only closing
Only opening
Opening and closing
If you force the gate
manually, the control
unit starts the motor to
restore the state of the
gate before forcing.
0.0 5.0
Pre-flashing only
active before closing
Buzzer
Buzzer
85 - PREFLASHING
86 - FLASHING LIGHT
Only closing
Normal
Light
Always
Normal
Control lamp
Always ON
Pre-flashing time
Off
Normal
1 240
20
88 - COURTESY LIGHT
In cycle
Courtesy light setting
from 1s to 4min.
Courtesy light in cycle
Off on
Off
5 100%
100%
89 - TRAFFIC LIGHT
RESERVATION
When setting this function
the pedestrian input will be
activated to work on the
auxiliary board SEM
(traffic light management).
90 - PEDESTRIAN OPENING
Setting from 5 to 100
= Start
91 - PEDESTRIAN PAUSE
Pause in pedestrian opening
same as in total opening
= Start
Off
Disabled
1 240
Setting from 1s to 4 min.
92 - TIMER
Off
On photo2
Off
On pedestrian entry
Transforms the selected
input in an input on
which to connect an
external clock.
Off
Off
On
The flashing light remains
ON with active timer and
open gate
The flashing light remains
OFF with the active timer
and open gate
87 - FLASHING LIGHT
AND TIMER
Always
AUX output always
power supplied
94 - 24V AUX (Programmable)
In cycle
In pause
Opening
Closing
AUX output power
supplied only during opening
AUX output power
supplied only during closing
AUX output power
supplied only during pause
AUX output active only
during cycle
Always
In cycle and fototest
AUX output only during cycle
with fototest function active
Autotest
Security test
Off
Off
93 - FIRE SWITCH
Disabled
On photo2
On pedestrian entry
Active on Photo 2
Active on pedestrian
8
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
MENU SP
Default
SET
Description
Set Value
95 - AUTOTEST
Photo1
Photo2
Photo1-2
Autotest active only on
Photo1
Autotest active only on
Photo2
Autotest active on
Photo1 and Photo2
Off
Off
Edge
Photo1 and Edge
All safe
Disabled
Autotest only on safety edge
Autotest photo 1 and
safety edge
Autotest photo 2 and
safety edge
Autotest photo 1, photo 2
and safety edge
Photo2 and Edge
Stop
97 - PHOTO1
Opening
Closing
Stop and close
Close
Pause reload
Active in opening
and closing
Photocell active in closing
Photocell active before
opening
The photocell gives a
command to close during
opening, pause and
closing
The photocell charging the
pausing time
The photocell stops in closing
and closes when released
Closing
Delay pause time
If the photocell is occupied
during opening, pause or
closing, the gate reopens
completely and closes
without observing the
pause time.
Shadow loop
Until occupied, with open
gate, it prevents reclosing.
It is switched off during
closing.
Stop
98 - PHOTO2
Opening
Closing
Stop and close
Close
Pause reload
Active in opening
and closing
Photocell active in closing
Photocell active before
opening
The photocell gives a
command to close during
opening, pause and
closing
The photocell charging the
pausing time
The photocell stops in closing
and closes when released
Delay pause time
If the photocell is occupied
during opening, pause or
closing, the gate reopens
completely and closes
without observing the
pause time.
Shadow loop
Until occupied, with open
gate, it prevents reclosing.
It is switched off during
closing.
Opening
9
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
MENU SP
Default
SET
Description
Set Value
100 - EDGE1
8K2
Edge is active and
protected by a 8k2 resistor
Normal N.C. contact
Normal
Normal
102 - EDGE1
Only closing
Opening and closing
Only opening
Active in opening
and closing
Active only in opening
Active only in closing
Opening
and
closing
Normal
104 - SELECT LIMIT SWITCH
Ext
Limit switch in automatic
recognition
With LSE card
0 10E9 0
100 10E4
10E4
107 - MAINTENANCE CYCLES
108 - PERFORMED CYCLES
Setting from 100 to
100000
Reports the executed
cycles. Keep pressed OK
to reset the cycles
1 10
Shows last event
(See alarms table)
106 - DIAGNOSTICS
112 - PASSWORD
- - - -
Allows the entering of a
password blocking the
control unit parameters
modification.
Press OK to exit the special menu.
The special menu switches off automatically after 20 minutes.
Note 1: The * indicates that the default value or the menu may change depending on the selected motor type.
Note 2: After initialization the parameters "motor type" and "limit switch type" remain son the value chosen in the setup
program.
- - - -
120 - BASIC MENU
Normal
PASSWORD ENTERING MANAGEMENT
With a new control unit all menus can be displayed and set and the password will be disabled.
Selecting one of the Menus and keeping UP and DOWN pressed at the same time for 5 seconds, you will access the SP Menu
containing the 112-PASSWORD Submenu.
Pressing OK in the 112-PASSWORD Menu, you will proceed with the entering of the numeric code of the 4-digit password.
Use UP and DOWN to increase or decrease the number, press OK to confirm it and you will pass automatically to the entering of
the next number. Pressing OK after the last entered number the word “Sure?” appears, confirm the activation of the password
and the message OK appears, pressing UP or DOWN instead you can cancel the operation and “No operation” will appear on the
display.
Once entered the password, it will be definitively activated, once the display switch off timeout has expired, or by turning off and
on again the control unit. Once the password has been activated, the menus of the display can be only displayed but not set. To
unlock them you must enter the correct password in the112-PASSWORD menu, if the password is wrong the message “Error”
will appear.
At this point, if the password has been entered correctly, the menus will be unlocked and it will be possible to change the
parameters of the control unit again.
If the control unit has been unlocked through 112-PASSWORD Menu, it is possible to enter a new and different password, using
the same entering process as for the first one; at this point, the old password will no longer be valid.
If the password has been forgotten, the only way to unlock the control unit is to contact the SEA technical assistance, which will
assess whether to provide the procedure to unlock the control unit or not.
Note: The password cannot be set through the Jolly or Jolly 2 terminal.
10
MENU
Description
Description
Start test
Stop test
Pedestrian
start test
Safety edge
test
Photocell 1
test
Photocell 2
test
Opening
limit switch
test
Closing
limit switch
test
The contact must be a N.O. Contact . When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.O. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
IThe contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. Contact or that the related limit switch is not occupied.
Exit menu
OK
OK
OK
MENU FUNCTION TABLE CHECK GATE 1 DG R1 INVERTER INPUTS
To access the Menu for input check keep pressed OK for about 5 seconds.
OK
Note: If the Stop, Photocell 1 and Photocell 2 contacts are not bridged in self-learning, they will be
deactivated and can be reactivated through this menu, without repeating times self-learning.
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
MENU FOR INPUT CHECK
UP
OK
UP
UP
UP
DOWN
DOWN
DOWN
OK
OK
OK
DOWN
Initial system
Software Version
Programming example
MENU
SEA
SET
- - -
- -
- - -
DISPLAY INPUT STATUS
When the segment
is ON during self-
learning, the input
status is closed or
OFF.
Start
Start
pedestrian
Stop
Limit
Switch
opening
motor
Photocell 1
Photocell 2
Edge
Limit
Switch
closing
motor
U.001
ITALIAN
LANGUAGE
ENGLISH
FRANCAIS
LIMIT SWITCH
CLOSING
LIMIT SWITCH
OPENING
START
EDGE1
PHOTO1
PHOTO2
PEDESTRIAN START
END
STOP
Enabled
Blocked
Enabled
Blocked
Enabled
Blocked
Enabled
Blocked
The settings of the control unit are made through the UP, DOWN and OK buttons. The UP and DOWN buttons to
scroll through the MENUS and SUBMENUS. By pressing OK you enter from MENU into SUBMENU and confirm the
choice.
Moving in the 1-LANGUAGE menu pressing the UP and DOWN buttons at the same time you access the SP MENU
for special settings.
Moving in the 1-LANGUAGE menu pressing the OK button for 5 seconds, you enter the CHECK MENU, where you
can check the operating status of all inputs.
11
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
RADIO TRANSMITTER SELF LEARNING
WITH RECEIVER ON BOARD OF CONTROL UNIT
!!
WARNING: Make the radio transmitters programming before you connect the antenna and insert the receiver into the
special CMR connector (if available) with turned off control unit.
With RF UNI and RF UNI PG module it will be possible to use both Coccinella Roll Plus transmitters and radio transmitters with fixed
code. The first memorized radio transmitter will determine the type of the remaining radio transmitters.
If the receiver is a Rolling Code, press twice the button of the radio transmitter that you want to program to memorize the first TX.
In the case of transmitters with fixed code it is necessary to press 1 time the button of the transmitter you want to program to store the first
remote control
Notes:
- Enter radio transmitters learning only when the working cycle stops and the gate is closed.
- You can store max. 2 of the available 4 functions. If the control unit receives a code which was already associated to another function it will be
updated with the new function.
16 USERS Whitout memory
800 USERS With additional memory MEMO
100 USERS Fixed code
800 USERS Roll Plus
800 UTENTI Fixed code
800 UTENTI Roll Plus
RF UNI
RF UNI PG
RF UNI PG
Old model without additional memory
New model with MEMO additional memory
1 2 3 4
0
1
2
3
TABLE EXAMPLE
Transmitter
button
Memory
location
Serial number Customer
1 2 3 4
0
1
2
3
Transmitter
button
Memory
location
Serial number Customer
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
UP
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
UP
MENU
SEA
SET
MENU
SEA
SET
UP
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
UP
MENU
SEA
SET
MENU
SEA
SET
UP
MENU
SEA
MENU
SEA
SET
MENU
SEA
SET
MENU
SEA
SET
SET
START
PEDESTRIAN
START
EXTERNAL
MODULE
STOP
DELETE A
TRANSMITTER
0
OK? OK
CLEAR
MEMORY
OK
PRESS
BUTTON
STORED
STORED
STORED
STORED
PRESS
BUTTON
PRESS
BUTTON
PRESS
BUTTON
If you want to program
the pedestrian
start as second
channel.
If you want to
delete a single
transmitter.
If you want to delete
the whole memory
If you want to program
the activation
of the LIGHT
output
as second channel.
Press the
button of the
transmitter
to be stored
Press the
button of the
transmitter
to be stored
Press the
button of the
transmitter
to be stored
Select with
UP or DOWN
the memory
location
to be deleted
and press OK
Press the
button of the
transmitter
to be stored
If you do not want to execute the cancellation,
press UP or DOWN to return to the
2-TRANSMITTERS menu.
Confirm the cancellation.
If you want to
program the
UNLOCH as
second channel.
MENU
SEA
SET
MENU
SEA
SET
UP
MENU
SEA
SET
UNLOCH
STORED
PRESS
BUTTON
Press the
button of the
transmitter
to be stored
If you want to
program the
STOP as
second channel.
OK
OK
OK
OK
OK
OK
OK
for 10 s.
MENU
SEA
SET
OK
TRANSMITTERS
OK
UP
MENU
SEA
SET
MENU
SEA
SET
If you want
to exit the
2-TRANSMITTERS
menu
Menu output
END
OK
OK
12
CS
N
C
N
S
RADIO TRANSMITTER SELF LEARNING
WITH RF FIX RECEIVER ON BOARD OF CONTROL UNIT
Connect the receiver on
the CNS connectors,
making sure that the
direction is the
one shown in the
illustration.
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
WARNING: Make the radio transmitters programming before you connect the antenna and insert the receiver
into the special CNS connector (if available) with turned off control unit.
With the RF FIX module it will be possible to use only radio controls with fixed code.
Select through the display 2-TRANSMITTERS and press OK, now select with the UP and DOWN buttons, the command to which
you want to associate the button (it is possible to associate max. 2 commands) and press OK to confirm the choice, now press the
button of the radio transmitter which you want to associate. If the storage is successful, the display will show “Stored” .
In the 2-TRANSMITTERS MENU it is possible to select “Start” (to associate a Start command), “Pedestrian start” (to associate a
Pedestrian Start ), “External Module” (For the activation of a contact on the EXP output), “Stop” (To associate the STOP command
to the TX), “Unloch” (to associate the release of the electric brake to the transmitter), “Delete a transmitters” (To delet the single
transmitter only if it is a Rolling Code Plus), “Clear memory” (To delete all TX), “End” (To exit menu 2-TRANSMITTERS).
To release the electric brake it is necessary to give three consecutive pulses, the 4th will reactivate the lock of the electric brake.
Notes:
- Enter radio transmitters learning only when the working cycle stops and the gate is closed.
- It will be possible to memorize up to max. 16 codes (buttons) adding the MEM memory it will be possible to store up to 496
different codes.
- You can store max. 2 of the available 4 functions. If the control unit receives a code which was already associated to another
function it will be updated with the new function.
DELETE TRANSMITTERS FROM THE RECEIVER
With modules different from RF FIX, it will be possible to delete only the entire memory of the receiver.
Proceed as follows: select from the menu 2-TRANSMITTERS: “Clear memory” and hold the OK button until the display shows
the message “OK”.
!!
13
TIMER
TX1
TX2
1 2 3 4 5 6 7 8
RX1
RX2
START
START PED.
STOP
-
C
CN1
9 10 11 12 13
CN1
11
12
9 10 11 12 13
CN1
-
-
11
11
12
12
11
12
+
3
4
6
5
6
6
7
6
8
START (N.O.) The
An impulse given to this contact opens and closes the automation depending on the selected logic, it can be given by a keyswitch, a keypad, etc.
To connect the other devices refer to the related instructions leaflets. (ie. loop detectors and proximity switches).
Note1: In DEADMAN logic keep pressed the Start for the opening of the automation.
Note2:
START is connected between connector 2 and 3 of the CN 1 terminal.
In the case of triggering a safety device the
timer will automatically reset after 6 seconds.
Holding
START starts the TIMER function, releasing the start, the operator repeats the pause and then performs the closing.
In 2 BUTTONS logic this button performs the opening.
STOP (N.C.) The STOP is connected between the clamps 2 and 5 of the CN1 terminal .
When pressing this button the motor immediately stops in any condition/position. To re-start the movement give a start command.
After a stop the motor always re-starts in closing.
Can be activated through the on-board display or through the Jolly programmer. In both cases it’s a N.O. contact which provoques the
opening of the automation keeping it open as long as it is activated. When it’s released, after having paused for the set pausing time the
gate recloses. The TIMER can be activated on the inputs FOTO2, PEDESTRIAN START or keeping busy the START input.
Note1: When activated on the pedestrian entry, the pedestrian will be OFF also on the radio transmitter.
Note2: In the event of an intervention of a security device during the timer (Stop, amperometric, Edge), a start impulse restors the
movement.
Note3: In case of no power supply with open gate and active Timer the control unit will restore its function, otherwise if during restoring of
the power supply the TIMER is not activated it will be necessary to give a start impulse for the reclosing.
PEDESTRIAN START (N.O.) The pedestrian start can be connected
between the conectors 2 and 4 of the CN1 terminal .
This input allows a partial opening, the opening space can be set through the
on-board display or through the JOLLY device.
Note1: The contact for partial opening is a N.O. Contact (Normally open).
Holding START starts the TIMER function, releasing the pedestrian start,
the operator repeats the pause and then performs the closing. In the case of
triggering a safety device the timer will automatically reset after 6 seconds.
Note2:In 2 BUTTONS logic it is necessary to keep pressed the Start Ped. to
re-close the automation.
Note3: In deadman logic this button executes the re-closing if you keep it
pressed.
Note4: When closed during pause, the gate will reclose only after this input
has been reopened.
TIMER activation: This input can be transformed into TIMER (See TIMER).
Nota5: When using the Sem card, the pedestrian input can be used as
priority in closing through the 89-TRAFFIC LIGHT RESERVATION
function.
+
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
START - STOP - PEDESTRIAN START - ANTENNA -
PHOTOCELL
Photocell 1 and Photocell 2 Connections
Note: If the photocells are not connected, it is not necessary put a jumper between the clamps (6 and 7
and/ou 6 and 8 of the CN1 terminal)
+ = 24V (Accessories) 500 mA max COM = 0V PH1 = Photocell contact 1
PH2 = Photocell contact 2
Note: For the autotest connect the TX to the AUX clamp and activate the Autotest function.
The default setting of the photocell 1 is in “Closing” and the one of the photocell 2 is in “Opening”.
The photocell 2 can also be set as TIMER (see TIMER function).
OPTIONS ON FOTO1 and FOTO2 adjustable on on- board display or with JOLLY terminal.
“Closing”: if occupied, reverses the movement in closing, during pause it prevent the closing.
“Opening”: If activated the photocell blocks the movement as long as it’s busy, when released
the opening continues.
“Stop”: When activated before the opening the photocell blocks the automation as long as it is
busy, during the opening it will be ignored. In closing the intervention of the photocell causes the
reopening.
“Stop and close”: in opening it is not active; in pause are activated it commands the closing
when released, otherwise it’s not active; in closing it stops the movement as long as it is busy,
when released the closing continues.
“Close”: The photocell stops the gate as long as it is occupied in both opening and closing,
when released it gives a closing command (Closing one second after release of the photocell).
“Pause reload”: If occupied, during pause it recharges the timer of pause. In closing it reverses
the movement.
“Shadow loop”: Photocell aktive only during pause.
“Delay pause time”: If the photocell is occupied during opening, pause or closing, the gate
reopens completely and closes without observing the pause time.
Options AUX 24V 500mA (Programmable) max can be set with on-
board Display or with Jolly device. It is possible to chose when having
tension on the AUX output. The options are: Always, In cicle, Opening,
Closing, In pause, Autotest, In cycle and fototest, Positive brake
management, Negative brake management, Negative brake management-
photocellule, Gate open warning light, Lock, Opening and open.
N.B: If you want the autotest just
connect the positive of the devices to
be tested on the input 10 (AUX) and
choose the device on which to
execute the test through the
Autotest” or In cycle and fototest
function.
14
AMPEROMETRIC MANAGEMENT
SAFETY EDGE AND FLASHING LAMP
SAFETY EDGE
Safety edges (EDGE) can be connected between the contacts 9 and 11 of CN1.
Pressing EDGE, the contact opens, causing a partial reversing of the gate in closing and opening.
Note1: If the edge contact is not used it must be
briged The EDGE input can be set: only in closing,
only in opening or in both directions.
Note2: It is possible to activate a balanced edge
8K2 through the on board display or through the
Jolly programmer, in such case the edge contact
will be controled by a specific resistance value,
detecting the possible involontary short circuit of
the device. In case of an imbalanced device a
special alarm will show on the on board display or
on the JOLLY programmer.
.
Note: it is possible to perform an Autotest also on
the powered radio edge.
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
Waring lamp Flash Led 24V (Accessories) 3W Max (Control lamp)
The warning lamp can be connected between the terminals 24V (Accessories) and FL (-) of CN1
It blinks once per second during opening and twice per second during closing, while it remains lit during
pause.
Throught the warning lamp it is also possible to identify alarm signals comming from the STOP,
PHOTOCELL 1, PHOTOCELL2 and EDGE devices. Through the on board display or the Jolly programmer
it is possible to activate the pre-flashing function and/or to modify the flashing light function choosing
between fixed flashing, control lamp or Buzzer.
The pre-flashing can be set from 0 to 5 s. or it is possible to have it only before closing.
Safety edge
in closing
10 11 12 13
1 2 3 4 5 6 7 8 9
CN1
12
13
11
9
FL (-)
24V (Accessories)
Common
+ -
AMPEROMETRIC DEVICE FOR ELECTROMECHANICAL OPERATORS
This control unit comes with an obstacle detection system working only on electromechanical operators allowing to
have the reversing on obstacles and the automatic detection of the stops.
Sensitivity adjustable from OFF to 99% inside the special menu. The more the percentage is high the more the
obstacle detection will be difficult.
ENCODER (CN5 Connector)
The Encoder allows the detection of the gate position and its reversing in case of obstacles. To use the ENCODER it
is necessary to enable it inside the special 32-ENCODER Menu. The sensitivity on the obstacle is adjustable from 0 -
99%. The higher the percentage is the more it will be difficult to detect the obstacle.
NOTE: If the Encoder is activated it is possible to visualize in the special menu the total memorized impulses and the
partial impulses executed by the motor.
POTENTIOMETER "GATE POSITION"
If the POSITION GATE is present on hydraulic motors it will be possible to have the inversion on obstacles by
adjusting the menus 33- MOTOR1 OPENING SENSITIVITY, 34- MOTOR1 CLOSING SENSITIVITY, 37-
SLOWDOWN SENSITIVITY.
ATTENTION: The first operation, after power failure will be for searching the mechanical stops at the end of the run.
15
DS
EXP
COURTESY
LIGHT
COURTESY LIGHT
AND POWER SUPPLY CONNECTIONS
Timing
from 0 to 4 min
(230V~ 50W Max),
during the cycle
it will be always turned on
POWER SUPPLY INPUT
NOTE: For power supply
connection follow the rules in
force.
DS1
DS2
RL4 RL3 RL2 RL1
L4
L3
L2
IC2
- M2+
1 CNP
CN1
L1
M1
24V~ / (ac/dc)
or
230V~
1 2 3 4 5 6 7 8
1
2
3
4
TRAFFIC LIGHT CARD CONNECTION
Connect on
EXP terminal
230Vac
Single-phase
!!
380Vac Three phase+N
!!
CN2
14 15 16 17 18 19 20
N L
CN3
R S T
N L
CN3
N R S T
230Vac
Single-phase
!!
230Vac Three phase
!!
Neutral
Line
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
16
FOUR LIMIT SWITCH WITH LSE CARD
Dip switch 1 = OFF
Dip switch 2 = ON
1 2
ON
OFF
On the GATE1 DG INV to activate the
EXT mode on Limit Switch Menu.
I1 = Closing limit switch (green cable)
I2 = Opening limit switch (yellow cable)
GND = Common electronic control unit (grey cable)
I3 = Slowdown closing limit switch (pink cable)
I4 = Slowdown opening limit switch (white cable)
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
Note: The motor is already
synchronized with the limit switches. If
you invert the motor, you have to also
invert the limit switches.
EXP
GATE1 DG INV
CONTROL UNIT
Display
1 2
ON
CN1
DS1
POTENC
M2
M1
1 2 4
P01 D1 P11 P02 D2 P12 I1
5 6 7
I2
GND
I3 I4
3 8 9 10 11
P01 to P12
NOT USED
NOT USED
Green
Yellow
Gray
Pink
White
POTENTIOMETER MANAGEMENT (Position Gate)
(Available from revision 013 only on prepared motors)
The position gate ensures the correct position of the gate and the inversion on the obstacle, helping the installer to pass the certification of the automation.
To connect the potentiometer you must use the LE card (Cod.23001256) and set with Dip Switches 1 and 2 both in OFF.
With the potentiometer it is possible to access the hidden DEBUG menu to check the maximum settable value as threshold in normal and slowdown speed.
To access this menu you have to press, in the menu that displays the firmware version, UP and OK at the same time until the menus VP1 speed of potentiometer 1
will appear.
To view the speed of the potentiometer on the related menu, press OK.
To exit the DEBUG menu go to END and press OK.
If the reading of the potentiometer is reversed relative to the movement of the motor, on the display will appear the alarm "Potentiometer direction" and you will
have to reverse the brown wire with the green one and repeat programming..
For a quick inversion on the obstacle you have to lower the sensitivity parameters.
1 2
ON
CN1
CNP
DS1
POTENC
M2
M1
1 2 4
P01 D1 P11 P02 D2 P12 I1
5 6 7
I2
GND
I3 I4
3 8 9 10 11
+ -
LE CARD
DS
EXP
D1 (White)
P01 (Green)
P11 (Brown)
Potentiometer 2
(Position Gate)
17
INVERTER MODULE CONNECTION
(Already wired)
(CMS) INVERTER
INTERFACE CONNECTOR
Insert on CN4
of the
Gate 1 Inverter
control unit
230Vac
Single-phase
!!
R S T
N L
CN3
230Vac Three phase
!!
M1
U
V
W
N R S T
SIGB
SIGA
COM
N L
CN3
Depending on the version
(230V / 380V)
380Vac Three phase+N
!!
Neutral
Line
230Vac
Single-phase
!!
INVERTER
MODULE
!!
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
18
Note 1: If in the diagnostics shows "Max. cycles reached ", do the maintenance and / or reset the
number of cycles performed.
Note2: To exit from the error messages, press OK. If the error persists, make all required checks for the
specific error and / or disconnect the device that generates the error to see if the error disappears.
At each opening and closing of the automation the flashing light will blink. It blinks once per second
during opening and twice per second during closing, while it remains lit during pause.
It is possible to view the alarms also on the flashing light or on the control lamp, simply by observing the
number of flashes emitted and verifying the reference in the table below:
ALARM DESCRIPTION
Signals Kind of alarm
Solutions
Inverter failure
24V Power supply
failure
AUX output voltage
Power supply failure
Self-test photocells
failure
Limit switch
activation failure
Flashing lamp failure
Make sure there are no short circuits on the wiring or on the
control unit and no overloads.
Make sure there are no short circuits on wiring or control unit
and no overload.
Check the network or the F2 fuse
Check the photocells operation and / or connections on the
control unit.
Check the operation of both limit switches and / or
correspondence between movement direction of the motor
and engaged limit switches.
Check connections and / or conditions of the lamp.
Blinks
9
2
3
4
Blinks
5
7
6
4 fast
Cause of alarm
Inverter failure
Photocell in closing
Photocell in opening
Safety edge
Cause of alarm
Stop
Max. Cycles reached
Collision in opening/closing
Limit switch fault
Check the connections between Gate 1 DG and inverter module.
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
FAILURE INVERTER
FAILURE24
FAILURE24VAUX
FAILURE NET
FAILURE SELF TEST
FAILURE LIMIT
SWITCH
FAILURE FLASHING LIGHT
FAILURE
POTENTIOMETER
Potentiometer failure
The message appears only if the potentiometer is ON and the
potentiometer (LE) card is broken or not connected.
19
Advises
Make sure all Safeties are turned ON
Problem Found Possibile Cause Solutions
Motor doesn’t respond to any
START impulse
Gate doesn’t move while the
motor is running
Gate doesn’t reach the complete
Open / Closed position
The gate opens but doesn’t
close
The gate doesn’t close
automatically
a.) Check the connected N.C. Contacts
b.) Burnt fuse
a.) The motor is in the released position
b.) There is an obstacle
a.) Pause time set to high
b.) Control unit in semi-autom. logic
a.) Wrong setting of the limit switches
b.) Error on programming
c.) Gate is stopped by an obstacle
a.) The contacts of the photocells are
connected and open
b.) The stop contact is connected and open
c.) The edge contact is open
a.) Check the connections or the jumpers
on the connections of the safety edge or
of the stop and of the photocell if connected
b.) Replace the burned fuse on the control unit
a.) Re-lock the motor
b.) Remove obstacle
a.) Adjust pause time
a.) Set limit switches
b.) Repeat programming
c.) Remove obstacle
a.) b.) c.) Check the jumpers or the
connected devices and the signals
indicated on the warning lamp
b.) Set the pause parameter on a different
value from the OFF
TROUBLE SHOOTING
Page for both instaler and user
WAREHOUSING TEMPERATURES
T
min
T
Max
Dampness
min
Dampness
Max
5% Not condensing 90% Not condensing
MAINTENANCE
Considering the number of working cycles and the kind of gate, if the gate has changed the clutches and doesn’t work it’s necessary to
periodically proceed, with the learning times reprogramming on the electronic control unit.
Periodically clean the optical systems of the photocells.
REPLACEMENTS
Any request for spare parts must be sent to:
SEA S.p.A. - Zona Ind.le, 64020 S.ATTO - Teramo - Italia
SAFETY AND ENVIRONMENTAL COMPATIBILITY
Disposal of the packaging materials of products and/or circuits should take place in an approved disposal facility.
REGULAR PRODUCT DISPOSAL (electric and electronic waste)
(It’s applicable in EU countries and in those ones provided with a differential waste collection)
The brand that you find on the product or on documentation signals that the product must not be disposed off together with other domestic
waste at the end of life cycle. In order to avoid any possible environmental or health damage caused by irregular waste disposal, we
recommand to separate this product from other forms of waste and to recycle it in a responsible way in order to provide the sustainable re-use of
material resources. Domestic users are invited to contact the retailer where the product has been purchased or the local office in charge of all
the information related to differential watse collection and recycling of this kind of product.
STORING
Materials handling must be made with appropriate vehicles..
WARRANTY LIMITS
SEA reserves the right to make any required modification or change to the products and/or to this manual without any advanced notice
obligation.
For the guarantee see the sales conditions on the official SEA price list.
- 20°C + 65°C
d.) Amperometric threshold too low
d.) Increase the current threshold parameter
GATE 1 DG R1
INVERTER
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

SEA Gate 1 DG R1 Manuale del proprietario

Categoria
Gate Opener
Tipo
Manuale del proprietario

in altre lingue