ProMinent DulcoFlow DFMa series Operating Instructions Manual

Tipo
Operating Instructions Manual
Ultrasonic Flow Meter
DulcoFlow
®
DFMa
Operating instructions
Part no. 986007 BA MAZ 014 01/11 EN
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.
986007, 1, en_GB
© 2010
ProMinent Dosiertechnik GmbH
Im Schuhmachergewann 5-11
69123 Heidelberg
Germany
Telephone: +49 6221 842-0
Fax: +49 6221 842-617
Internet: www.prominent.com)
2
Supplementary information
Read the following supplementary information
in its entirety! Should you already know this
information, you have an even greater need of
the Operating Instructions.
The following are highlighted separately in the
document:
n Enumerated lists
Instructions
ð
Outcome of the instructions
- see (reference)
Information
This provides important information
relating to the correct operation of the
system or is intended to make your work
easier.
Safety information
Safety information is identified by pictograms -
see "Safety Chapter".
General non-discriminatory approach
In order to make it easier to read, this docu‐
ment uses the male form in grammatical struc‐
tures but with an implied neutral sense. It is
aimed equally at both men and women. We
kindly ask female readers for their under‐
standing in this simplification of the text.
Supplemental instructions
3
Table of contents
1 Identity code............................................................................................................................ 6
2
About this product................................................................................................................... 8
3 Safety chapter......................................................................................................................... 9
4 Storage and transport........................................................................................................... 12
5 Device overview.................................................................................................................... 13
6 Functional description........................................................................................................... 14
7 Assembly and installation...................................................................................................... 15
7.1 Installation.................................................................................................................... 15
7.2 Hydraulic Installation.................................................................................................... 15
7.3 Electrical Installation..................................................................................................... 17
8 Settings ................................................................................................................................ 20
8.1 Operating unit............................................................................................................... 20
8.1.1 LCD screen............................................................................................................... 20
8.1.2 LEDs.......................................................................................................................... 20
8.1.3 Control keys.............................................................................................................. 20
8.2 Checking adjustable variables...................................................................................... 23
8.3 Operating menu overview............................................................................................ 24
8.4 Changing to adjustment mode..................................................................................... 25
8.4.1 "Mode" main menu.................................................................................................... 25
8.4.2 "Set-up" main menu.................................................................................................. 25
8.4.3 "Calibration" main menu............................................................................................ 29
8.4.4 "Zero set" main menu................................................................................................ 40
8.4.5 "Info" main menu....................................................................................................... 41
8.4.6 "Language" main menu............................................................................................. 41
9 Start up.................................................................................................................................. 42
10 Maintenance, repair and disposal......................................................................................... 44
10.1 Maintenance............................................................................................................... 45
10.2
Repairs....................................................................................................................... 45
10.3 Disposal...................................................................................................................... 45
11 Troubleshooting.................................................................................................................... 46
11.1
DulcoFlow
®
error........................................................................................................ 47
11.2 Pump error................................................................................................................. 48
11.3 All Other Faults........................................................................................................... 49
Table of contents
4
12 Technical data....................................................................................................................... 50
13 Dimensions sheet.................................................................................................................. 53
14 EC Declaration of Conformity................................................................................................ 54
15
Decontamination declaration................................................................................................. 55
16 Index..................................................................................................................................... 56
Table of contents
5
1 Identity code
Product range DulcoFlow
®
flow meter
DFMa Type For pump product ranges
05 Beta, gamma/ L: 1000 - 0413/0713; delta: 1608 - 1612
08 Beta, gamma/ L: 0220/0420 - 0232; delta: 1020 - 0280
Seal material
E EPDM
T PTFE
V FPM
Hydraulic connection
1 6/4 mm
2 8/5 mm
3 12/9 mm
Electrical connection
A 2 m European
B 2 m Swiss
C 2 m Australian
D 2 m USA
Signal output
0 No output
1 Current output
2 Counter output
Version
0
With ProMinent
®
Logo
2
Without ProMinent
®
Logo
Accessories
0 No accessories
Identity code
6
Identity code
7
2 About this product
The flow meter DulcoFlow
®
is intended for use
in measuring pulsing volume flows in the range
from 0.1 to 80 l/h. All parts coming into contact
with flow media are made from PVDF. This
ensures that aggressive media can also be
measured without problem. The device is
installed approximately 30 cm after the pump in
the metering line. Interfering influences, such
as air bubbles, are identified and forwarded to
the analysis unit as an error message. With the
delta, it can only be used with the fast metering
stroke version.
The DulcoFlow
®
flow meter can not only be
used for recording and measurement of volume
flows, but also for monitoring individual
metering strokes. In this case the pump is cali‐
brated to the lifting volume set at the pump. A
lower and upper limit can be entered, which if
exceeded or undershot, results in no feedback
to the pump. This creates an error message.
The connection to the pump takes place via the
input for the "Flow Control" dosing monitor
The device is designed for wall mounting.
About this product
8
3 Safety chapter
Explanation of the safety information
The following signal words are used in these
operating instructions to identify different
severities of a hazard:
Signal
word
Meaning
WARNI
NG
Denotes a possibly hazardous sit‐
uation. If this is disregarded, you
are in a life-threatening situation
and this can result in serious inju‐
ries.
CAU‐
TION
Denotes a possibly hazardous sit‐
uation. If this is disregarded, it
could result in slight or minor inju‐
ries or material damage.
Warning signs denoting different types of
danger
The following warning signs are used in these
operating instructions to denote different types
of danger:
Warning signs Type of danger
Warning – high-
voltage.
Warning – danger
zone.
Correct and proper use
n The device may only be used with liquid
metering chemicals.
n The device can only be used with pulsing
liquid flows with a clear zero flow.
n The device may only be used after it has
been correctly installed and commissioned
in accordance with the technical data and
specifications contained in the operating
instructions.
n Observe the general limitations with regard
to viscosity limits, chemical resistance and
density - see also ProMinent resistance list
(In the product equipment catalogue or at
www.prominent.com
)!
n Any other uses or modifications are pro‐
hibited.
n The device is not suitable for measuring
continuous liquid flows.
n The device may not be used to measure
gaseous media or solids.
n The device may not be used with combus‐
tible media without appropriate protective
measures.
n The device may not be used with explo‐
sive media.
n The device may not be used with radioac‐
tive media.
n The device is not intended for exterior
applications without use of suitable protec‐
tive equipment.
n The device should only be operated by
trained and authorised personnel, see the
following "Qualifications" table.
n You are obliged to observe the information
contained in the operating instructions at
the different phases of the system's
service life.
Safety chapter
9
Safety information
WARNING!
Danger of electric shock
A mains voltage may exist inside the
housing.
If the housing has been damaged,
you must disconnect the device from
the mains immediately. It may only be
returned to service after an authorised
repair.
WARNING!
Warning of dangerous or unknown feed
chemical
Should a dangerous or unknown feed
chemical be used: It may escape from the
hydraulic components during maintenance
work.
Take appropriate protective measures
before working on the device (safety
glasses, safety gloves, ...). Observe
the safety data sheet for the feed
chemical.
Drain and flush the hydraulic parts
before working on the device.
CAUTION!
Warning of feed chemical spraying around
Feed chemical can spray out of the
hydraulic components if they are manipu‐
lated or opened due to pressure in the
hydraulic and adjacent parts of the system.
Disconnect the pump of the device
hydraulic system from the mains
power supply and ensure that it
cannot be switched on again by unau‐
thorised persons.
Depressurise the system before com‐
mencing any work on hydraulic parts.
CAUTION!
Danger of personnel injury and material
damage
The use of untested third party parts can
result in personnel injuries and material
damage.
Only fit parts to the device, which
have been tested and recommended
by ProMinent.
NOTICE!
Warning of illegal operation
Observe the regulations that apply where
the device is installed.
Information in the event of an emergency
In an emergency, disconnect the device from
the mains!
If feed chemical escapes, also depressurise the
device hydraulic system. Adhere to the safety
data sheet for the feed chemical.
Safety chapter
10
Qualification of personnel
Activity Qualification level
Storage, transport,
unpacking
Instructed personnel
Installation, installa‐
tion of hydraulic
system
Technical personnel
Electrical installation Electrician
Operation Instructed personnel
Maintenance Technical personnel
Repairs Customer service -
authorised by ProMi‐
nent
Decommissioning,
disposal
Technical personnel
Troubleshooting Technical personnel,
electrician, instructed
personnel
Technical personnel
A qualified employee is deemed to be a person
who is able to assess the tasks assigned to him
and recognise possible hazards based on his/
her technical training, knowledge and experi‐
ence, as well as knowledge of pertinent regula‐
tions.
Electrician
Electricians are deemed to be people, who are
able to complete work on electrical systems
and recognize and avoid possible hazards
independently based on their technical training
and experience, as well as knowledge of perti‐
nent standards and regulations. Electricians
should be specifically trained for the working
environment in which the are employed and
know the relevant standards and regulations.
Electricians must comply with the provisions of
the applicable statutory directives on accident
prevention.
Instructed personnel
An instructed person is deemed to be a person
who has been instructed and, if required,
trained in the tasks assigned to him/her and
possible dangers that could result from
improper behaviour, as well as having been
instructed in the required protective equipment
and protective measures.
Customer Service department
Customer Service refers to service technicians,
who have received proven training and have
been authorised by ProMinent
®
to work on the
system.
Safety chapter
11
4 Storage and transport
Safety information
WARNING!
Only return the device for repair in a
cleaned state and with flushed hydraulic
parts - refer to the chapter "Decommis‐
sioning"!
Only send the unit complete with a filled in
Decontamination Declaration form. The
Decontamination Declaration constitutes
an integral part of an inspection / repair
order. A unit can only be inspected or
repaired when a Decontamination Declara‐
tion Form is submitted that has been com‐
pleted correctly and in full by an authorised
and qualified person on behalf of the oper‐
ator.
The "Decontamination Declaration Form"
can be found in the Appendix or under
www.prominent.com
.
NOTICE!
Danger of material damage
The device can be damaged by incorrect
or improper storage or transportation!
The device should only be stored or
transported in a well packaged state -
preferably in its original packaging.
The packaged unit should also only
be stored or transported in accord‐
ance with the stipulated storage con‐
ditions.
The packaged unit should be pro‐
tected from moisture and the ingress
of chemicals.
Ambient conditions
Data Value Unit
Minimum storage and transport temperature -10 °C
Maximum storage and transport temperature +50 °C
Air humidity < 95 % rel.
humidity*
* non-condensing
Storage and transport
12
5 Device overview
1
2
4
5
3
Fig. 1: Overview of equipment DulcoFlow
®
with arrows showing flow
1 Control elements - see chapter "Settings" -
"Operating unit"
2 Mains connection
3 Signal output (option)
4 Feed chemical inlet
5 Feed chemical outlet
Device overview
13
6 Functional description
The DulcoFlow
®
flow meter measures the
volume flow of pulsing flows. The ultrasonic,
time of flight measurement method is used. For
the time of flight measurement, a sound signal
is alternately transmitted in and against the
direction of flow. The time difference is then a
measure of the mean flow velocity. Use of the
ultrasound measurement method automatically
compensates any temperature induced
changes in the medium. Operation without
moving parts guarantees a long service life and
wear-free operation.
The DulcoFlow
®
calculates the mass flow from
the volume flow and the density of the feed
chemical.
Additionally the DulcoFlow
®
can measure the
pressure surges of the metering pump and
hence replace a dosing monitor such as the
Flow Control. A metering pump such as the
gamma/ L or delta
®
can use these signals as
acknowledge pulses for its individual strokes. If
the acknowledge pulses are missing or if the
capacity exceeds the specified limit values, the
metering pump stops after an adjustable
number of missing pulses and goes into fault
mode - see metering pump operating instruc‐
tions.
The DulcoFlow
®
gives the flow reading, stroke
feedback, or error messages via the various
output types.
Functional description
14
7 Assembly and installation
Safety information
WARNING!
Carry out the assembly work before the
electrical installation is undertaken.
WARNING!
Observe the information in the "Technical
data" chapter.
WARNING!
Danger of an electric shock
If the device is used outdoors without a
cover or weatherproof roof, water may be
able to collect on the seals and penetrate
the housing or direct sunlight may cause
the housing to be corroded.
Always use a cover or weatherproof
roof when using the unit outdoors.
CAUTION!
Warning of illegal operation
Observe the regulations that apply where
the unit is to be installed.
The device is resistant to normal atmos‐
pheres in plant rooms.
7.1 Installation
Install the device so that the hose between
it and the pump is approximately 30 cm
long.
This ensures it measures accurately.
Mount the device vertically.
This ensures it measures accurately.
Mount the device vertically on the wall
using both eyes on the housing.
Do not forget the washers.
7.2 Hydraulic Installation
CAUTION!
Warning of escaping feed chemical
Feed chemicals can escape in the event
that the hose lines are incorrectly installed.
Only use original hoses with the
specified hose dimensions.
Avoid reducing the hose sizes.
Assembly and installation
15
Flow direction
The flow direction through the device goes
from the bottom to the top.
Injection valves, back pressure
valves, relief valves
Injection valves, back pressure valves or
relief valves must not have any effect on
the measurement.
Relief valves
It is best to install a relief valve before the
flow meter, so that the displayed flow or
flow volume actually corresponds to the
value which is being metered into the
system if the relief valve triggers.
Hydraulic Dampers
Hydraulic dampers, like accumulators,
inline dampers or bladder accumulators /
diaphragm accumulators must not have
any effect on the measurement.
A zero flow must be available.
The damping must not push the flow mean
value beneath the measurement threshold.
Installing the hosing:
1. Cut off the ends of the hoses (6) so that
they are straight.
2. Unscrew the union nut (5) and push
over the hose together with the clamp
ring (4).
3. Push the hose end (6) up to the stop
over the nozzle (3).
4. Tighten the union nut (5).
5. Pull on the hose (6) and tighten up the
union nut (5).
1
3
2
4
5
6
P_MAZ_0041_SW
Fig. 2: Installing the hose line
1 Connector
2 Seal
3 Nozzle
4 Clamp ring
5 Union nut
6 Hose
Assembly and installation
16
P_MAZ_0040_SW
2
PD
1
3
4
5
6
7
Fig. 3: DulcoFlow
®
hydraulic system
1 Target use
2 Pressure maintenance device
3 Hydraulic Damper
4
DulcoFlow
®
5 Overflow device
6 Metering pump
7 Storage tank
7.3 Electrical Installation
WARNING!
Danger of electric shock
The use of a residual current circuit
breaker drastically increases survival
chances should persons come into contact
with the mains voltage due to an electrical
accident.
Always fit a residual current circuit
breaker on-site.
A metering pump, PLC or other devices can be
connected to the flow meter.
The following alternative electrical outputs are
available via cable:
n Current output (identity code characteristic
"signal output "1"):
n Counter output (identity code characteristic
"signal output "2"):
Assembly and installation
17
Current output
The following can be signalled via the current output (standard signal output (mA)):
n Instantaneous flow
n Fault
Technical data:
Data Value Unit
Current* 0/4 .. 20 mA
Maximum load 400
* zero volt connection
Counter output as stroke feedback output
The counter output as stroke feedback output
can be used to signal stroke feedback, pro‐
vided it is set accordingly - see chapter "Set‐
tings".
1. To report stroke feedback at the
metering pump such as gamma/ L and
delta
®
, plug the cable from the flow
meter to the pump in the "dosing mon‐
itor" terminal.
ð
The identifier for the dosing monitor
must appear on the LCD screen of
the pump.
2. If it does not appear, make the neces‐
sary settings at the metering pump.
Assembly and installation
18
Counter output as frequency output
The counter output as frequency output can be used to signal flow or an error, provided it is set
accordingly - see chapter "Settings".
1. Remove the connected socket.
2. Remove the insulation of the leads to match the terminals of the other device.
3. Crimp on a suitable cable end sleeve.
ð
In this format, the cable can be connected to another device.
4.
Connect the cable to both devices in accordance with the wiring diagram. DulcoFlow
®
wiring
diagram - see appendix.
Technical data:
Data Value Unit
Voltage with open contacts < 30 V
Current with closed contacts < 10 mA
Residual voltage with closed contacts < 0.7 V
Switching frequency < 10 kHz
Lead Function
brown Supply Voltage
white Error signal
blue Frequency signal
black Mass
Assembly and installation
19
8 Settings
8.1 Operating unit
P_MAZ_0039_SW
V: 1145.69 mL
Q:
502.13
mL/h
i
DulcoFlow
®
1
2
3
4
Fig. 4: Operating unit DulcoFlow
®
1 LCD display
2 Status LED
3 Control keys
4 Stroke feedback LED
8.1.1 LCD screen
The LCD screen comprises a two-line display.
8.1.2 LEDs
The status LEDs (left) shows the following
information:
LED Information
green Status OK
orange Warning
red Error
The stroke feedback LED (right) shows the fol‐
lowing information:
LED Information
off No pressure surge identified
green, illumi‐
nated
Pressure surge detected -
within tolerance
red, illumi‐
nated
Pressure surge detected -
outside tolerance
8.1.3 Control keys
The control keys are designated as follows:
Key Designation
i
[ i ]
[DOWN]
[UP]
[P]
Settings
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57

ProMinent DulcoFlow DFMa series Operating Instructions Manual

Tipo
Operating Instructions Manual

in altre lingue